
doi: 10.1002/dta.1906
pmid: 26489966
This study compared the sensitivity of various separation and ionization methods, including gas chromatography with an electron ionization source (GC‐EI), liquid chromatography with an electrospray ionization source (LC‐ESI), and liquid chromatography with a silver ion coordination ion spray source (LC‐Ag+CIS), coupled to a mass spectrometer (MS) for steroid analysis. Chromatographic conditions, mass spectrometric transitions, and ion source parameters were optimized. The majority of steroids in GC‐EI/MS/MS and LC‐Ag+CIS/MS/MS analysis showed higher sensitivities than those obtained with other analytical methods. The limits of detection (LODs) of 65 steroids by GC‐EI/MS/MS, 68 steroids by LC‐Ag+CIS/MS/MS, 56 steroids by GC‐EI/MS, 54 steroids by LC‐ESI/MS/MS, and 27 steroids by GC‐ESI/MS/MS were below cut‐off value of 2.0 ng/mL. LODs of steroids that formed protonated ions in LC‐ESI/MS/MS analysis were all lower than the cut‐off value. Several steroids such as unconjugated C3‐hydroxyl with C17‐hydroxyl structure showed higher sensitivities in GC‐EI/MS/MS analysis relative to those obtained using the LC‐based methods. The steroids containing 4, 9, 11‐triene structures showed relatively poor sensitivities in GC‐EI/MS and GC‐ESI/MS/MS analysis. The results of this study provide information that may be useful for selecting suitable analytical methods for confirmatory analysis of steroids. Copyright © 2015 John Wiley & Sons, Ltd.
Doping in Sports, Spectrometry, Mass, Electrospray Ionization, Reproducibility of Results, Performance-Enhancing Substances, Reference Standards, Urinalysis, Gas Chromatography-Mass Spectrometry, Substance Abuse Detection, Anabolic Agents, Limit of Detection, Predictive Value of Tests, Tandem Mass Spectrometry, Calibration, Humans, Steroids, Chromatography, Liquid
Doping in Sports, Spectrometry, Mass, Electrospray Ionization, Reproducibility of Results, Performance-Enhancing Substances, Reference Standards, Urinalysis, Gas Chromatography-Mass Spectrometry, Substance Abuse Detection, Anabolic Agents, Limit of Detection, Predictive Value of Tests, Tandem Mass Spectrometry, Calibration, Humans, Steroids, Chromatography, Liquid
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 22 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 10% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Top 10% |
