doi: 10.1002/ccd.28149
pmid: 30790436
AbstractObjectiveTo understand the clinical and hemodynamic response of patients with stenotic versus regurgitant prosthetic mitral valve degeneration to transseptal transcatheter mitral valve‐in‐ring/‐valve replacement (TMVR).BackgroundPatients with prosthetic mitral valve repair/replacement failure frequently present high‐risk surgical challenges. TMVR has been employed as an alternative to surgery.MethodsForty‐four patients with stenotic/regurgitant degeneration of prior prosthetic mitral annuloplasty and replacement (38) underwent mitral TMVR. Clinical, echocardiographic, and invasive hemodynamic monitoring was conducted at baseline and follow‐up.ResultsRelative to patients with regurgitant degeneration (28), patients with stenotic degeneration had baseline higher mitral valve gradients (12 ± 4 vs. 7 ± 3 mmHg, p < 0.01) and smaller areas (1.0 ± 0.4 vs. 1.5 ± 0.4 cm2, p = 0.01). TMVR yielded significant reduction in left atrial v‐wave pressures in stenotic and regurgitant cohorts (−7 ± 11, p = 0.03, and −11 ± 12 mmHg, p < 0.01, respectively) and significant, sustained symptomatic improvement. Intracardiac pressures overall, including left ventricular end diastolic pressures, remained elevated.ConclusionDespite baseline differences in valvular disease, TMVR leads to significant hemodynamic and clinical improvement in both stenotic and regurgitant prosthetic mitral valve disease. In both cohorts, TMVR reduced intracardiac pressures to similar postprocedural levels, but pressures remained supranormal. This outcome suggests a multifactorial process defines the pathophysiology of patients undergoing TMVR, including contributions from prosthetic degeneration, changes in left atrial compliance, and diastolic dysfunction, and highlights the need to consider such factors in patient evaluation and treatment.
Aged, 80 and over, Heart Valve Prosthesis Implantation, Male, Cardiac Catheterization, Mitral Valve Annuloplasty, Time Factors, Hemodynamics, Mitral Valve Insufficiency, Recovery of Function, Prosthesis Design, Prosthesis Failure, Treatment Outcome, Risk Factors, Heart Valve Prosthesis, Humans, Mitral Valve, Mitral Valve Stenosis, Female, Aged
Aged, 80 and over, Heart Valve Prosthesis Implantation, Male, Cardiac Catheterization, Mitral Valve Annuloplasty, Time Factors, Hemodynamics, Mitral Valve Insufficiency, Recovery of Function, Prosthesis Design, Prosthesis Failure, Treatment Outcome, Risk Factors, Heart Valve Prosthesis, Humans, Mitral Valve, Mitral Valve Stenosis, Female, Aged
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 7 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 10% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Top 10% |