Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Catheterization and ...arrow_drop_down
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
Catheterization and Cardiovascular Interventions
Article . 2001 . Peer-reviewed
License: Wiley Online Library User Agreement
Data sources: Crossref
versions View all 2 versions
addClaim

Measurement of radial artery spasm using an automatic pullback device

Authors: F, Kiemeneij; B U, Vajifdar; S C, Eccleshall; G, Laarman; T, Slagboom; R, van der Wieken;

Measurement of radial artery spasm using an automatic pullback device

Abstract

AbstractCurrent evaluation of radial artery spasm (RAS), a frequent finding during the transradial approach for coronary angiography and angioplasty (TRA), is subjective. A quantitative measure of RAS will help in evaluation and comparison of management strategies. The objectives of the study were to assess the feasibility and safety of using an automatic pullback device (APD) for removal of transradial introducer sheaths and to establish a parameter to quantify RAS. In 50 consecutive transradial procedures, the APD was used to measure the force required for sheath removal. The mean maximal pullback force (MPF) was 0.53 ± 0.52 kg (range, 0.1–3.0 kg). In 48 (96%) cases, the MPF was reached within the first 5 sec of pullback. All patients with clinical RAS (n = 4) had an MPF greater than 1.0 kg, while the remaining had an MPF less than 1.0 kg. All patients with severe pain during sheath removal (n = 3) had an MPF greater than 1.0 kg, while no patient with an MPF less than 1.0 kg had severe pain. It is feasible and safe to remove transradial introducer sheaths using the APD. The MPF is achieved within the first 5 sec of pullback and is a reliable parameter to quantify RAS. An MPF more than 1.0 kg correlates with clinical RAS and is associated with severe pain during sheath removal. Cathet Cardiovasc Intervent 2001;54:437–441. © 2001 Wiley‐Liss, Inc.

Keywords

Adult, Aged, 80 and over, Male, Spasm, Equipment Safety, Data Collection, Equipment Design, Middle Aged, Severity of Illness Index, Microcomputers, Radial Artery, Feasibility Studies, Humans, Female, Prospective Studies, Vascular Diseases, Device Removal, Aged

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    45
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Top 10%
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 10%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Top 10%
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
45
Top 10%
Top 10%
Top 10%
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!