Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Clinical Anatomyarrow_drop_down
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
Clinical Anatomy
Article . 2023 . Peer-reviewed
License: Wiley Online Library User Agreement
Data sources: Crossref
Clinical Anatomy
Article . 2024
versions View all 2 versions
addClaim

Accuracy analysis of traditional acupoint location and the coincidence of cutaneous arterial perforators and acupoints

Authors: Chunxia Guo; Yongguang Zhang; Zhiwei Ding; Rong Han; Xuwen Jiao; Jinlian Hu;

Accuracy analysis of traditional acupoint location and the coincidence of cutaneous arterial perforators and acupoints

Abstract

AbstractSeveral reports have shown a coincidence relationship between perforators and acupoints. However, there have been few previous reports of objective experimental methods to verify the reliability of the accuracy of acupoint location (APL) with nearby perforators. This research aimed to determine the internal agreement of the APL of five acupuncturists and to analyze the coincidence rate of acupoints with nearby perforators. Three two healthy volunteers were recruited with the inclusion and exclusion criteria. Three TCM clinical physicians determined acupoints in areas of the lower limb of participants. Two microsurgeons sketched corresponding regions based on the most common skin flap operation sites, located bone markers, and drew the skin flap axis. Doppler ultrasound was used to mark the perforator point and the distances measured for both points. There is no significant difference in the distance between the acupoints and perforators localization in different groups, and there are significant differences between the angle formed by acupoints and penetrators in all groups. All the points located by the traditional Chinese medicine (TCM) therapists are distributed around the dot. The distance between the coordinate point (A‐B) of 溫溜 Wēnliū (LI7) localization is the largest, reaching 16.6 mm. The accuracy of the acupoint location of each physician is limited by the clinical experience of physicians, and the difference among them is significant. There is a certain correspondence between the location of acupoints and perforators, which needs further studies to confirm.

Related Organizations
Keywords

Male, Adult, Lower Extremity, Humans, Reproducibility of Results, Female, Arteries, Acupuncture Points, Healthy Volunteers, Skin

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    4
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Top 10%
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Top 10%
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
4
Top 10%
Average
Top 10%
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!