The relationship between the frequency with which 0.125% and 1.0% prednisolone acetate ophthalmic suspensions are instilled and the anti-inflammatory effect they achieve in the cornea was studied. Within the time limits of the experimental protocol, application of the drug at four-hour intervals failed to produce an effect while hourly administration of both concentrations of the corticosteroid produced a substantial anti-inflammatory effect. Instillation at 15-minute intervals resulted in a significantly (P less than .05) greater reduction of the polymorphonuclear leukocytes invading the cornea than did administration of the medication every hour. If five doses of prednisolone acetate were applied topically at one-minute intervals each hour, both concentrations of this corticosteroid produced a therapeutic effect in the cornea equal to that achieved by administration of the drug every 15 minutes.
Keratitis, Male, Administration, Topical, Prednisolone, Drug Administration Schedule, Cornea, Animals, Female, Rabbits, Ophthalmic Solutions
Keratitis, Male, Administration, Topical, Prednisolone, Drug Administration Schedule, Cornea, Animals, Female, Rabbits, Ophthalmic Solutions
citations This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 22 | |
popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |