Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/ http://cyberleninka....arrow_drop_down
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
addClaim

This Research product is the result of merged Research products in OpenAIRE.

You have already added 0 works in your ORCID record related to the merged Research product.

Клинико-функциональные результаты применения отечественной офтальмохирургической системы с усовершенствованными алгоритмами управления витреотомом

Клинико-функциональные результаты применения отечественной офтальмохирургической системы с усовершенствованными алгоритмами управления витреотомом

Abstract

В настоящем исследовании изучены результаты 82 витреоретинальных хирургических вмешательств, выполненных по стандартной трехпортовой методике с применением инструментов калибра 25G. Первая группа пациентов (45 глаз) прооперирована на офтальмохирургической системе «Оптимед Профи» с использованием cortexи core-алгоритмов высокоскоростной витрэктомии, вторая группа (37 глаз) на системе Nidek CV 24000AP. У всех пациентов витрэктомия проведена успешно, интраи послеоперационные осложнения наблюдались в единичных случаях. Практически во всех случаях удалось добиться анатомического результата, отмечена положительная динамика зрительных функций. Благодаря уменьшению тракционных воздействий и более эффективной аспирации при работе системы «Оптимед Профи» риск ятрогенного повреждения сетчатки был минимален.

This study evaluates the results of 82 vitreoretinal surgical procedures. The procedures were performed by a standard three-port technique with the use of 25G instruments. In the first group (45 patients), the surgery was performed using an ophthalmological surgical system “Optimed Profi” with cortexand core-algorithms of high-speed vitrectomy. In the second group (37 patients) the surgery was performed using Nidek CV 24000AP. Vitrectomy was successful in all cases, intraand postoperative complications were observed in a few cases. In almost all cases anatomical results and improvement of visual function were achieved. Due to reduction of traction and more efficient aspiration of “Optimed Profi” the risk of iatrogenic retina damage was minimal.

Keywords

ВИТРЭКТОМИЯ, ВИТРЕОТОМ, ОФТАЛЬМОХИРУРГИЧЕСКАЯ СИСТЕМА

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    0
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
0
Average
Average
Average