
The results of phacoemulsification of a cataract with IOL Acrysof Restor Aspheric® (+3,0) and Acrysof Restor Toric® SND 1T4 in 48 patients between 2010-2013 are analyzed in the research.Monocular implantation of IOL Acrysof Restor Aspheric (+3,0) was carried out in 36 patients (36 eyes), binocular in 7 patients (14 eyes), monocular implantation of IOL Acrysof Restor Toric® SND 1 T4 in 5 patients (5 eyes). In the postoperative period the average visual acuity afar (BVDA) was about 0.92±0,06 and was estimated as perfect by 96% of patients, in close (BVNA) -0.62±0.06 and estimated as perfect by 83.3%. The patients with binocular implantation of IOL Acrysof Restor Aspheric® (+3,0) were best of all satisfied with the results of the operation. The need for additional correction (with glasses) of visual acuity in close (BVNA) was noted by 2 patients (4.2%) during 6 months of dynamic follow-up.
В работе проанализированы результаты факоэмульсификации катаракты с имплантацией интраокулярных линз (ИОЛ)Acrysof Restor Aspheric® (+3,0) и Acrysof Restor Toric® SND 1 Т4 у 48 пациентов за 2010 2013 годы.Монокулярная имплантация ИОЛ Acrysof Restor Aspheric (+3,0) была проведена у 36 пациентов (36 глаз), бинокулярная у 7 пациентов (14 глаз), ИОЛ Acrysof Restor Toric SND 1 Т4 монокулярно была имплантирована у 5 больных. В послеоперационном периоде средняя острота зрения вдаль (BVDA) составила 0,92±0,06 и в 96% случаев была оценена пациентами на «отлично», вблизи (BVNA) 0,62±0,06 и в 83,3% оценена на «отлично». Удовлетворенность результатами операции выразили пациенты с бинокулярной имплантацией ИОЛ Acrysof Restor Aspheric® (+3,0). Необходимость в дополнительной очковой коррекции для работы вблизи через 6 месяцев динамического наблюдения отмечена у 2 (4,2%) больных.
ПСЕВДОАККОМОДИРУЮЩИЕ ИОЛ, ФАКОЭМУЛЬСИФИКАЦИЯ КАТАРАКТЫ, КАЧЕСТВО ЗРЕНИЯ
ПСЕВДОАККОМОДИРУЮЩИЕ ИОЛ, ФАКОЭМУЛЬСИФИКАЦИЯ КАТАРАКТЫ, КАЧЕСТВО ЗРЕНИЯ
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 0 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |
