image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/ Вестник Иркутского г...arrow_drop_down
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
addClaim

This Research product is the result of merged Research products in OpenAIRE.

You have already added 0 works in your ORCID record related to the merged Research product.

Определение места повреждения на четырехфазных воздушных линиях электропередачи высокого напряжения по параметрам аварийного режима при одностороннем замере

Определение места повреждения на четырехфазных воздушных линиях электропередачи высокого напряжения по параметрам аварийного режима при одностороннем замере

Abstract

Рассматривается четырехфазная воздушная линия электропередачи. Получены аналитические выражения, связывающие параметры аварийного режима в начале линии с параметрами аварийного режима в месте повреждения через симметричные составляющие. Разработаны односторонние методы определения места повреждения для воздушной линии с распределенными и сосредоточенными параметрами, обладающие нулевой методической погрешностью при точном задании сопротивления системы противоположного конца линии. Выполнена оценка влияния распределенности параметров воздушной линии, а также погрешности в определении сопротивления удаленного конца линии на погрешность определения места повреждения.

The article examines a four-phase overhead power transmission line. It receives analytical expressions that connect fault parameters in the sending end with the parameters in the fault localization through symmetrical components. The author develops one-sided fault location methods for distributed and lumped overhead lines that have a zero error if remote end system impedance is correct. The effect of overhead line parameter distribution as well as the incorrect remote end overhead line impedance on fault location accuracy is estimated.

Keywords

ЧЕТЫРЕХФАЗНАЯ ВОЗДУШНАЯ ЛИНИЯ ЭЛЕКТРОПЕРЕДАЧИ, ОПРЕДЕЛЕНИЕ МЕСТА ПОВРЕЖДЕНИЯ, ЛИНИЯ С РАСПРЕДЕЛЕННЫМИ ПАРАМЕТРАМИ, ЛИНИЯ СО СОСРЕДОТОЧЕННЫМИ ПАРАМЕТРАМИ, ВЕЩЕСТВЕННОСТЬ ПЕРЕХОДНОГО СОПРОТИВЛЕНИЯ, FOUR-PHASE HIGH VOLTAGE OVERHEAD (POWER TRANSMISSION) LINE

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    0
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
0
Average
Average
Average
gold