Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/ South Ural State Uni...arrow_drop_down
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
addClaim

This Research product is the result of merged Research products in OpenAIRE.

You have already added 0 works in your ORCID record related to the merged Research product.

Математическое моделирование электрического поля катодно-поляризуемого трубопровода с учетом внешнего и внутреннего изоляционного покрытия

Authors: Krizskiy, V.N.; Alexandrov, P.N.; Kosarev, O.V.; Luntovskaya, Y.A.;

Математическое моделирование электрического поля катодно-поляризуемого трубопровода с учетом внешнего и внутреннего изоляционного покрытия

Abstract

Владимир Николаевич Кризский, доктор физико-математических наук, профессор, кафедра информатики и компьютерных технологий, Санкт-Петербургский горный университет (г. Санкт-Петербург, Российская Федерация), krizsky@rambler.ru. Павел Николаевич Александров, доктор физико-математических наук, ведущий научный сотрудник, Институт физики Земли им. О.Ю. Шмидта РАН (г. Москва, Российская Федерация), Alexandr@igemi.troitsk.ru. Олег Валерьевич Косарев, кандидат технических наук, доцент, кафедра ин- форматики и компьютерных технологий, Санкт-Петербургский горный университет (г. Санкт-Петербург, Российская Федерация), oleg.v.kosarev@yandex.ru. Яна Алексеевна Лунтовская, аспирант, кафедра информационных систем и вычислительной техники, Санкт-Петербургский горный университет (г. Санкт- Петербург, Российская Федерация), yanaluntovskaya@yandex.ru. V.N. Krizskiy1, P.N. Alexandrov2, O.V. Kosarev1, Y.A. Luntovskaya1 1Saint-Petersburg Mining University, Saint-Petersburg, Russian Federation 2Schmidt Institute of the Earth physics of the Russian Sciences Academy, Moscow, Russian Federation E-mail: krizsky@rambler.ru, Alexandr@igemi.troitsk.ru, oleg.v.kosarev@yandex.ru, yanaluntovskaya@yandex.ru Формирование математических моделей для корректного расчета параметров систем катодной защиты с целью защиты трубопровода от образования коррозии на металле труб является актуальной задачей. Однако далеко не все модели учитывают необходимые факторы, оказывающие влияние на достоверность рассчитываемых показателей, на основании которых проводится анализ и принятие соответствующих решений о дальнейшей эксплуатации трубопровода. Авторами статьи рассмотрена задача расчета электрических параметров системы катодной защиты подземного трубопровода, находящегося в однородном полупространстве, с учетом переходного сопротивления внешнего и внутреннего покрытия изоляции. Formation of mathematical models for correct calculation of cathodic protection system parameters in order to protect pipelines from corrosion formation on pipe metal is an urgent task. However, not all models take into account the necessary factors influencing the reliability of calculated indicators, on the basis of which the analysis and appropriate decisions about further pipeline operation are made. The authors of the article considers a task of calculation of electric parameters of cathodic protection system for underground pipeline, located in a homogeneous half-space taking into account transition resistance of external and internal layers of insulation. To solve this problem the discretization method was used.

Keywords

519.632 [УДК 004.942], математическое моделирование электрического поля, main pipeline, внешнее и внутреннее сопротивление изоляции, external and internal insulation resistance, cathodic protection, mathematical modeling of electric field, катодная электрохимическая защита, магистральный трубопровод

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    0
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
0
Average
Average
Average
Green