Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/ Electronic Sumy Stat...arrow_drop_down
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
addClaim

This Research product is the result of merged Research products in OpenAIRE.

You have already added 0 works in your ORCID record related to the merged Research product.

Магніторезистивні властивості нанорозмірних плівкових матеріалів: варіювання вимірювальних струмів та мінімізація електронних шумів

Authors: Volkov, Serhii Oleksandrovych; Tkach, Olena Petrivna; Odnodvorets, Larysa Valentynivna; Khyzhnia, Yaroslava Volodymyrivna;

Магніторезистивні властивості нанорозмірних плівкових матеріалів: варіювання вимірювальних струмів та мінімізація електронних шумів

Abstract

Розроблені схема і програмне забезпечення електронного блока для варіювання величини вимірювального струму та мінімізації електронних шумів в автоматизованому лабораторному комплексі для вимірювання магнітоопору нанорозмірних плівкових матеріалів. Проведене дослідження магніторезистивних властивостей плівок на основі Co та Al або Cu, Fe та Pd або Au різного фазового складу із загальною товщиною від 20 до 150 нм при різних струмах вимірювання. Установлено, що незалежно від фазового складу плівкових матеріалів при величині вимірювального струму 10 і 100 мкА від плівок спостерігається нестабільний електричний сигнал несиметричної форми з невизначеним нульовим максимумом. Найбільш ефективним для усіх плівкових зразків є величина вимірювального струму 10 мА, при якому сигнал стає симетричним і стабільним. Разработаны схема и программное обеспечение электронного блока для варьирования величины измерительного тока и минимизации электронных шумов в автоматизированном лабораторном комплексе для измерения магнитосопротивления наноразмерных пленочных материалов. Проведено ис- следование магниторезистивных свойств пленок на основе Co и Al или Cu, Fe и Pd или Au разного фазового состава с общей толщиной от 20 до 150 нм при различных токах измерения. Установлено, что независимо от фазового состава пленочных материалов при величине измерительного тока 10 и 100 мкА от пленок наблюдается нестабильный электрический сигнал несимметричной формы с неопределенным нулевым максимумом. Наиболее эффективным для всех пленочных образцов является величина измерительного тока 10 мА, при котором сигнал становится симметричным и стабильным. The circuit and software of the electronic block for varying the magnitude of the measuring current and minimization of electronic noise in the automated laboratory complex for measuring of the magnetoresistance in nanodimentional film materials have been designed. Investigation of the magnetoresistive properties of films based on Co and Al or Cu, Fe, and Pd or Au different phase structure with a total thickness of 20 to 150 nm at different measuring currents were performed. It was established that irrespective of the phase composition of the film materials at the value of the measuring current of 100 mA and 10 from films of unstable electrical signal asymmetric shape with a maximum zero uncertain is observed. The most effective for all film samples is measuring current 10 mA, at which the signal becomes a symmetrical and stable.

Related Organizations
Keywords

nanodimentional film materials, магниторезистивные свойства, four-measuring circuit, измерительный ток, наноразмерные пленочные материалы, нанорозмірні плівкові матеріали, вимірювальний струм, measuring the current, стабилизация электрического сигнала, магніторезистивні властивості, четырехточечная схема измерения, stabilization of the electrical signal, magnetoresistive properties, чотирьохточкова схема вимірювання, стабілізація електричного сигналу

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    0
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
0
Average
Average
Average
Green