Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao IEEE Transactions on...arrow_drop_down
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
IEEE Transactions on Biomedical Engineering
Article . 2001 . Peer-reviewed
License: IEEE Copyright
Data sources: Crossref
DBLP
Article
Data sources: DBLP
versions View all 3 versions
addClaim

This Research product is the result of merged Research products in OpenAIRE.

You have already added 0 works in your ORCID record related to the merged Research product.

Multichannel ECG compression using multichannel adaptive vector quantization

Authors: Shaou-Gang Miaou; Heng-Lin Yen;

Multichannel ECG compression using multichannel adaptive vector quantization

Abstract

Adaptive vector quantization (AVQ) is a recently proposed approach for electrocardiogram (ECG) compression. The adaptability of the approach can be used to control the quality of reconstructed signals. However, like most of other ECG compression methods, AVQ only deals with the single-channel ECG, and for the multichannel (MC) ECG, coding ECG signals on a channel by channel basis is not efficient, because the correlation across channels is not exploited. To exploit this correlation, an MC version of AVQ is proposed. In the proposed approach, the AVQ index from each channel is collected to form a new input vector. The vector is then vector quantized adaptively using one additional codebook called index codebook. Both the MIT/BIH database and a clinical Holter database are tested. The experimental results show that, for exactly the same quality of reconstructed signals, the MC-AVQ performs better than single-channel AVQ in terms of bit rate. A theoretical analysis supporting this result is also demonstrated in this paper. For the same and relatively good visual quality, the average compressed data rate/channel is reduced from 293.5 b/s using the single-channel AVQ to 238.2 b/s using the MC-AVQ in the MIT/BIH case.

Related Organizations
Keywords

Electrocardiography, Signal Processing, Computer-Assisted, Algorithms

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    21
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Top 10%
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 10%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
21
Top 10%
Top 10%
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!