Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/ Известия высших учеб...arrow_drop_down
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
versions View all 3 versions
addClaim

This Research product is the result of merged Research products in OpenAIRE.

You have already added 0 works in your ORCID record related to the merged Research product.

THE DETERMINATION OF THE KIND OF PHASE-TO-PHASE SHORT CIRCUIT IN CURRENT LINE PROTECTION OF 6–35 KV

Authors: F. A. Romaniuk; O. A. Huryanchyk; M. A. Shevaldin; V. S. Kachenya;

THE DETERMINATION OF THE KIND OF PHASE-TO-PHASE SHORT CIRCUIT IN CURRENT LINE PROTECTION OF 6–35 KV

Abstract

The methods of determining the kind of phase-to-phase short circuit (SC) on the lines of 6–35 kV for improvement the technical perfection of their current protections are surveyed. Preference is given to the method of determining damages according to the relative unbalance the operating currents. The possibility of using the phase currents or their differences for this purpose is demonstrated. The method of computational experiment was used to investigate the influence of the DC load line and transition resistance at the failure site on the relative asymmetry of the currents that ultimately determines the reliability of the establishment of the kind of SC. It is discovered that when the phase currents are used to determine the type of the failure higher sensitivity to remote two-phase SC is achieved. However, in this case, the accuracy of determining the type of failure is more affected by currents of the line load. Determination of failure with the use of differences of phase currents is less sensitive to remote two-phase SC. However, this provides less impact on the accuracy of determining the type of failure of load line currents. Transition resistance at the failure site shifts the relative unbalance of the currents to the area of twophase SC. It is established that despite the kind of a remote SC in parallel lines the proposed methods provide accurate determination of types of failure that simultaneously occurs on the monitored line. When failures are superpositioned, one of which is on one of the parallel lines near the common bus and the other second on the monitored bus, the kind of the SC, determined by any of the proposed methods may differ from the actual one. It depends on the types of resulting failures, the combinations of shutting phases, the steady-state current distribution in the network and other factors. The proposed methods make it possible to determine the kind of phase-to-phase SC, in the worst case, for a time not exceeding the period of industrial frequency.

Related Organizations
Keywords

Токовая защита, overcurrent protection, load current, Relative unbalance, Короткое замыкание, Переходное сопротивление, difference of phase currents, fast response, phase current, Phase current, Overcurrent protection, Фазный ток - разность, kind of short circuit, Phase current - difference, relative unbalance, Transition resistance, transition resistance, Фазный ток, Short circuit, Hydraulic engineering, Engineering (General). Civil engineering (General), Load current, Относительная несимметрия, Ток нагрузки, TA1-2040, TC1-978

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    1
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 10%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
1
Average
Top 10%
Average
gold