image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao University of Southe...arrow_drop_down
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
Therapeutic Drug Monitoring
Article . 2014 . Peer-reviewed
Data sources: Crossref
versions View all 4 versions
addClaim

This Research product is the result of merged Research products in OpenAIRE.

You have already added 0 works in your ORCID record related to the merged Research product.

Quantitation of Metformin in Human Plasma and Urine by Hydrophilic Interaction Liquid Chromatography and Application to a Pharmacokinetic Study

Authors: Nielsen, Flemming; Hougaard Christensen, Mette Marie; Brøsen, Kim;

Quantitation of Metformin in Human Plasma and Urine by Hydrophilic Interaction Liquid Chromatography and Application to a Pharmacokinetic Study

Abstract

We describe an analytical method for the quantification of the widely used antihyperglycemic agent, metformin, in human plasma and urine. The separation was performed using isocratic hydrophilic interaction liquid chromatography on a Luna hydrophilic interaction liquid chromatography column (125 × 4.6 mm, 3 μm). The sample preparation was accomplished by solid-phase extraction. Validation of the method was performed in the range 10-2000 ng/mL for plasma and 5-30 mcg/mL for urine. The methods were linear within the investigated range (r(2) > 0.988). Within-day repeatability ranged from 3.1% to 7.5% in plasma and 1.6% to 6.2% in urine. Between-day reproducibility ranged from 2.9% to 5.3% in plasma and 0.6% to 1.8% in urine. The inaccuracy expressed as bias ranged from -3.1% to 1.9% in plasma and from -7.2% to 0.7% in urine. The lower limit of quantification for metformin in plasma was 5 ng/mL and in urine was 40 ng/mL. The method was therefore considered to be precise, accurate, reproducible, and sensitive enough to be appropriate for pharmacokinetic studies of metformin. The applicability of the method for human pharmacokinetic studies was demonstrated by dosing a healthy male volunteer with 500-mg metformin hydrochloride as a single oral dose; plasma and urine concentrations were measured for 24 hours.

Related Organizations
Keywords

Male, Chromatography, Metformin/analysis, Chromatography, Liquid/methods, Reproducibility of Results, Urine, Plasma/chemistry, Sensitivity and Specificity, Healthy Volunteers, Metformin, Plasma, Urine/chemistry, Limit of Detection, Liquid/methods, Humans, Hypoglycemic Agents, Hydrophobic and Hydrophilic Interactions, Hypoglycemic Agents/analysis, Chromatography, Liquid

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    19
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Top 10%
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
19
Average
Average
Top 10%
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!