Background: Dynamic preload parameters such as pulse pressure variation (PPV) and stroke volume variation (SVV) have widely been used as accurate predictors for fluid responsiveness in patients under mechanical ventilation. To circumvent the limitation of decreased cyclic change of intrathoracic pressure, we performed an intermittent PEEP challenge test to evaluate whether PPV or SVV can predict fluid responsiveness during one-lung ventilation (OLV). Methods: Forty patients undergoing OLV were analyzed. Baseline hemodynamic variables including PPV and SVV and respiratory variables were recorded after chest opening in lateral position under OLV (T1). Five minutes after application of PEEP 10 cmH2O, the parameters were recorded (T2). Thereafter, PEEP was withdrawn to 0 cmH2O for 5 minutes (T3), and fluid loading was performed with balanced crystalloid solution 6 mL/kg of ideal body weight for 5 minutes. Five minutes after completion of fluid loading, all variables were recorded (T4). The patient was classified as fluid responder if SV increased ≥10% after fluid loading and as non-responder if SV increased <10%. Results: Prediction of fluid responsiveness was evaluated with area under the receiver operating characteristic (ROC) curve (AUC). Change in stroke volume variation (ΔSVV) showed AUC of 0.9 (P < 0.001), 95% CI = 0.82-0.99, sensitivity = 88%, specificity = 82% for discrimination of fluid responsiveness. Change in pulse pressure variation (ΔPPV) showed AUC of 0.88 (P < 0.001), 95% CI = 0.78-0.97, sensitivity = 83%, specificity = 72% in predictability of fluid responsiveness. Cardiac index and stroke volume were well maintained after PEEP challenge in non-responders while they increased in responders. Conclusions: ΔPPV and ΔSVV induced by PEEP challenge are reliable parameters to predict fluid responsiveness as well as very good predictors of fluid unresponsiveness during OLV.
Adult, Male, one-lung ventilation, Intraoperative Complications / etiology, stroke volume variation, 610, Blood Pressure, Pulmonary Surgical Procedures, Pulmonary Surgical Procedures / methods, Positive-Pressure Respiration, Young Adult, fluid responsiveness, Fluid Therapy / methods*, Humans, Intraoperative Complications / prevention & control, Prospective Studies, Intraoperative Complications, Aged, One-Lung Ventilation / adverse effects*, Intraoperative Care, Pulmonary Surgical Procedures / adverse effects*, Stroke Volume, Middle Aged, Prognosis, Intraoperative Complications / diagnosis*, Positive-Pressure Respiration*, One-Lung Ventilation, Treatment Outcome, ROC Curve, pulse pressure variation, Fluid Therapy, Female, One-Lung Ventilation / methods, Esophageal Doppler, Intraoperative Care / methods, positive end-expiratory pressure, Research Paper
Adult, Male, one-lung ventilation, Intraoperative Complications / etiology, stroke volume variation, 610, Blood Pressure, Pulmonary Surgical Procedures, Pulmonary Surgical Procedures / methods, Positive-Pressure Respiration, Young Adult, fluid responsiveness, Fluid Therapy / methods*, Humans, Intraoperative Complications / prevention & control, Prospective Studies, Intraoperative Complications, Aged, One-Lung Ventilation / adverse effects*, Intraoperative Care, Pulmonary Surgical Procedures / adverse effects*, Stroke Volume, Middle Aged, Prognosis, Intraoperative Complications / diagnosis*, Positive-Pressure Respiration*, One-Lung Ventilation, Treatment Outcome, ROC Curve, pulse pressure variation, Fluid Therapy, Female, One-Lung Ventilation / methods, Esophageal Doppler, Intraoperative Care / methods, positive end-expiratory pressure, Research Paper
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 4 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 10% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |