Downloads provided by UsageCounts
The necessity and possibility of creating a dosimetric channel for determining the direction to the source of penetrating gamma-radiation in the nuclear situation monitoring system have been substantiated. The experimental assessment of a reduced error of the device for determining the direction to pulsed sources of radiation using a spherical absorber and CdTe detectors was carried out. These detectors can be used effectively only if there is appropriate electronic equipment, constructed in accordance with their characteristics and spectral-temporal characteristics of highly intense pulsed radiation. The direction to high-intensity pulsed radiation of linear accelerator Varian Clinac 600C (USA) by telluride-cadmium detectors was determined in the pulsed mode. This allowed conducting an experiment to determine the dependence of the coefficient of proportionality of recording pulses from each detector on the angle of direction to the source of pulsed radiation of the linear accelerator. A reduced error was assessed by comparing the received experimental data with a theoretical dependence based on a physical and mathematical model. It was recommended to divide the entire range of angles from 0° to 360° into five sub-ranges, in which three or two proportionality coefficients are responsible for determining the angle in space on gamma sources. The maximum reduced error does not exceed 10 % and the maximum angle error is not more than 8.4°. The most accurate determining of the angle to a radiation source can be carried out in the presence of a theoretically calculated and experimental database of proportionality coefficients for all angles in space and energy of radiation sources
визначення напрямку; гамма-випромінювання; напівпровідникові детектори; система моніторингу ядерної обстановки, UDC 502.55:621.039.7, direction determination; gamma-radiation; semiconductor detectors; nuclear situation monitoring system, определение направления; гамма-излучения; полупроводниковые детекторы; система мониторинга ядерной обстановки
визначення напрямку; гамма-випромінювання; напівпровідникові детектори; система моніторингу ядерної обстановки, UDC 502.55:621.039.7, direction determination; gamma-radiation; semiconductor detectors; nuclear situation monitoring system, определение направления; гамма-излучения; полупроводниковые детекторы; система мониторинга ядерной обстановки
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 4 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 10% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |
| views | 5 | |
| downloads | 2 |

Views provided by UsageCounts
Downloads provided by UsageCounts