Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/ Журнал нано- та елек...arrow_drop_down
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
versions View all 2 versions
addClaim

This Research product is the result of merged Research products in OpenAIRE.

You have already added 0 works in your ORCID record related to the merged Research product.

Investigations on the Optical-Electrical-Thermal Characteristics of RGB LEDs

Authors: Srividya, R.; Srinivasan, C.R.; Winston, Netto;

Investigations on the Optical-Electrical-Thermal Characteristics of RGB LEDs

Abstract

Відведення тепла є основною проблемою, яка викликає занепокоєння при роботі зі світлодіодами великої потужності. Якщо не контролювати, оптичні та електричні характеристики освітлювального приладу можуть постраждати. Більш висока температура переходу спричиняє коливання прямої напруги, світлових потоків, корельованої колірної температури, колірної точки та пікової довжини хвилі. Виробники світлодіодів мають свої робочі діапазони для температури переходу і струму збудження. Світлодіоди, які працюють за рамками робочого діапазону струму, спочатку можуть забезпечувати високий світловий потік, але температура переходу може збільшуватися поза вказаним діапазоном, що призводить до дуже швидкого погіршення світлового потоку. Крім того, підвищені температури переходів можуть серйозно вплинути на термін служби та надійність світлодіодів. Отже, вимірювання та контроль температури переходу в максимальному робочому діапазоні через відповідну теплову конструкцію є життєво важливими для уникнення погіршення продуктивності освітлювального приладу. У статті представлені результати експериментів, проведених для вимірювання температури переходу та аналізу її впливу на електричні та оптичні параметри світлодіодів RGB в межах максимальної робочої температури. Heat dissipation is the main problem of concern when working with high power light emitting diodes. If not controlled, the optical and electrical performance of the luminaire can get affected. A higher junction temperature induces variations in forward voltage, luminous lux, correlated color temperature, color point and peak wavelength. LED manufacturers have their operating ranges for junction temperature and driving current. Operating LEDs beyond the operating range of current may initially provide high luminous flux, but junction temperature might increase beyond the range specified, resulting in very fast degradation of luminous flux. Also, elevated junction temperatures can severely affect the lifetime and reliability of LEDs. Hence, measurement and control of junction temperature within the maximum operating range through appropriate thermal design are vital for avoiding performance degradation of the LED luminaire. This paper shows an insight on the experimentations carried out to measure the junction temperature and analyze its effect on the electrical and optical parameters of RGB LEDs within the maximum operating temperature.

Keywords

відведення тепла, світловий потік, світлодіод, luminous flux, LED, heat dissipation, forward voltage, пряма напруга, junction temperature, температура переходу

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    0
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
0
Average
Average
Average
Green
gold