
AbstractPurposeIt was hypothesized that robotic arm‐assisted total knee arthroplasty (RA‐TKA) using additionally a gap‐balancing instrumentation will show high accuracy in executing the planning in femoral and tibial component placement throughout the range of knee motion (ROM) during TKA surgery.MethodsProspectively collected data were analysed for patients undergoing RA‐TKA. A cruciate retaining cemented design was implanted using the MAKO® robotic system. Lower limb alignment at 0°, 30°, 45°, 60° and 90° of flexion was recorded at the beginning of surgery and finally after implantation of the components. A ligament tensioner was inserted after tibial precut to measure the extension and flexion gap, and final component placement was planned based on 3D CT images. Femoral and tibial component placement was measured in all three planes.ResultsA total of 104 patients were included (mean age 69.4 ± 9 years; 44 male, 60 female). The difference in component placement after planning and final implantation showed less valgus of 0.7° ± 1.4° (p < 0.001), less external rotation of 0.6° ± 1.9° (p = 0.001) and less flexion of 0.9° ± 1.8° (p < 0.001) for the femoral component. The tibial component was placed in more varus of 0.2° ± 0.9° (p = 0.056) and more posterior slope of 0.5° ± 0.9° (p < 0.001). The lower limb alignment in extension was 4.4° ± 5.2° of varus of the native knee and changed to 1.2° ± 1.9° of varus after TKA (p < 0.01).ConclusionRobotic‐assisted TKA helps to achieve the target of alignment and component placement very close to the planning. It allows optimal component placement of off‐the‐shelf implants respecting patient's specific anatomy.Level of EvidenceLevel II.
Male, Knee Joint, Tibia, Middle Aged, Osteoarthritis, Knee, Female [MeSH] ; Tibia/surgery [MeSH] ; Aged [MeSH] ; Knee Prosthesis [MeSH] ; Knee/surgery [MeSH] ; Humans [MeSH] ; KNEE ARTHROPLASTY ; Knee Joint/surgery [MeSH] ; Osteoarthritis, Knee/surgery [MeSH] ; functional alignment ; MAKO ; Middle Aged [MeSH] ; joint line ; total knee arthroplasty ; Male [MeSH] ; Range of Motion, Articular [MeSH] ; robotics ; Robotic Surgical Procedures/methods [MeSH] ; Arthroplasty, Replacement, Knee/methods [MeSH] ; ligament tension, Robotic Surgical Procedures, MAKO; functional alignment; joint line; ligament tension; robotics; total knee arthroplasty, Humans, Female, Knee, Range of Motion, Articular, Arthroplasty, Replacement, Knee, Knee Prosthesis, Aged
Male, Knee Joint, Tibia, Middle Aged, Osteoarthritis, Knee, Female [MeSH] ; Tibia/surgery [MeSH] ; Aged [MeSH] ; Knee Prosthesis [MeSH] ; Knee/surgery [MeSH] ; Humans [MeSH] ; KNEE ARTHROPLASTY ; Knee Joint/surgery [MeSH] ; Osteoarthritis, Knee/surgery [MeSH] ; functional alignment ; MAKO ; Middle Aged [MeSH] ; joint line ; total knee arthroplasty ; Male [MeSH] ; Range of Motion, Articular [MeSH] ; robotics ; Robotic Surgical Procedures/methods [MeSH] ; Arthroplasty, Replacement, Knee/methods [MeSH] ; ligament tension, Robotic Surgical Procedures, MAKO; functional alignment; joint line; ligament tension; robotics; total knee arthroplasty, Humans, Female, Knee, Range of Motion, Articular, Arthroplasty, Replacement, Knee, Knee Prosthesis, Aged
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 22 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 10% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Top 10% |
