We propose to research the causes of blood pressure measurement variability, and hence develop and evaluate improved measurement techniques, leading to the development of a prototype novel intelligent blood pressure measurement device that we will validate and assess clinically. High blood pressure is one of the leading cardiovascular risk factors for coronary artery disease, congestive heart failure, renal disease and stroke, and is a contributory factor in 30% of all deaths in the UK, and 4 million NHS bed days annually. Despite the importance of blood pressure measurement and its very widespread use, it is one of the most poorly performed diagnostic measurements in clinical practice. A single blood pressure measurement often determines the treatment (or non-treatment) received, in spite of high variability between measurements. However, consecutive blood pressure measurements in the same individual vary significantly, whether the measurements are taken manually or automatically. Our own research has shown that manual blood pressure measurements often vary by more than 10 mmHg between consecutive recordings. Measurement errors can seriously compromise diagnosis. A major review in the Journal of the American Medical Association (JAMA) estimated that a 5 mmHg error would result in 21 million Americans being denied treatment or 27 being exposed to unnecessary treatment, depending on the direction of the error. At the heart of this research proposal are observations we have made which will be able to detect potential measurement variability. We have seen a strong association between blood pressure variability and variability of the pressure pulses present in the arm cuff during blood pressure measurement. These observations have led to the proposal in this application, to research and develop techniques for an intelligent blood pressure measurement device that will use information about variability obtained from the cuff. The techniques developed will have intellectual property (which is currently being pursued) and potential for incorporation in electronic manual and automatic blood pressure devices. Measurement of stable clinical blood pressure will be the important achievement, giving clinical confidence in the measurement. Common disturbances that can influence clinical blood pressure measurement variability include heart rate changes, frequent ectopic beats, arrhythmias, patient movement, respiratory disturbances, coughing, talking and muscle tension. Our own research has shown that these disturbances are associated with changes in the oscillometric pulses in the cuff pressure. With stable data we see a smooth decrease in cuff pressure, along with a smooth variation in the amplitude of the small oscillometric pulses superimposed on the main descent of the cuff pressure curve. (These are the pulses analysed by automated blood pressure devices, and visible as pulsations of the mercury column during cuff deflation for manual measurements.) When blood pressure is varying we see deviations from these smooth pulse characteristics. We are in a unique position to investigate the influence of disturbances on blood pressure measurement variability. We have an extensive database comprising more than 1300 pre-recorded cuff pressure and oscillometric pulse pressure waveforms, recorded clinically in a variety of different subject groups with a wide range of blood pressures, together with auscultatory pressures measured simultaneously and independently by two trained members of our research group. Currently there are no publicly accessible databases of oscillometric waveforms. Our database was obtained as part of a European Union funded multi-centre international research consortium to develop a simulator for evaluating the accuracy of non-invasive blood pressure (NIBP) devices by enabling real, previously-recorded oscillometric waveforms to be regenerated. The data and simulator have important roles in the proposed project.
<script type="text/javascript">
<!--
document.write('<div id="oa_widget"></div>');
document.write('<script type="text/javascript" src="https://www.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=ukri________::35f7525862f9a77e9cd0f70962679ccd&type=result"></script>');
-->
</script>
<script type="text/javascript">
<!--
document.write('<div id="oa_widget"></div>');
document.write('<script type="text/javascript" src="https://www.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=ukri________::35f7525862f9a77e9cd0f70962679ccd&type=result"></script>');
-->
</script>
Clinical need High blood pressure is one of the leading cardiovascular risk factors for coronary artery disease, congestive heart failure, renal disease and stroke. It is a contributory factor in 30% of all deaths in the UK, with 4 million NHS bed days annually. A major review in the Journal of the American Medical Association (JAMA) estimated that a 5 mmHg error would result in 21 million Americans being denied treatment or 27 million being exposed to unnecessary treatment, depending on the direction of the error. The importance of blood pressure measurement is without doubt, but it is still one of the most poorly performed diagnostic measurements in clinical practice.Blood pressure measurement Manual auscultatory blood pressure measurement has changed little over the past 100 years. It contains three main elements: a cuff, pressure display and stethoscope. The cuff encircles the upper arm to occlude the brachial artery, and is deflated with a control, allowing the blood to flow again as the pressure is released. In spite of, or perhaps because of, its simplicity, it is still the most accurate measurement technique. The current International Standards shows that automated blood pressure devices can have an inaccuracy in comparison with manual measurement of +/- 16 mmHg (95% confidence interval), which is not adequate for clinical diagnostic decisions. Guidelines from the three main clinical European Societies addressed the need to re-establish manual measurement. This was further reinforced by the UK Department of Health when they issued a Medical Device Alert, requiring all clinical users to have access to a manual device so that accurate measurements are taken when required.The research problem Manual measurement relies highly on the skills of the trained users to identify the Korotkoff sounds associated with systolic and diastolic blood pressure (SBP and DBP) using the stethoscope. The proposed research will develop novel engineering solutions to achieve easy and accurate manual blood pressure measurement. SME collaboration The applicant is Chair of the British Standards Institute committee on sphygmomanometers and represents the UK on the International Standards Committee (joint International Organization for Standardization, and International Electrotechnical Commission) and has been active in this field for over 25 years. Our Newcastle research group has worked with the only UK manufacturer of sphygmomanometers, the family firm AC Cossor & Son (Surgical) Ltd, cooperating closely and successfully to produce the novel electronic patented Accoson greenlight 300 with a very clear display to make the reading of the measurement much easier, and to display the cuff deflation rate(also patented). These features have produced dramatic improvements, and have been led by UK industry. The only feature still to be improved is the use of the stethoscope. This is complex and requires much basic research before any new prototype device could be proposed. Our proposal to this Healthcare Partnerships will tackle this problem.Our goal In this proposal we will research techniques to aid and improve the identification of systole and diastole in manual blood pressure measurement. This research will study our existing unique database of recorded Korotkoff sounds, develop algorithms to help accentuate key differences in Korotkoff features at systole and diastole, set up a laboratory system to allow investigation of other sensors, investigate more discriminatory ways of presenting the sensor output, and prospectively evaluate the techniques proposed. There is enormous scope for improving this 100 year old acoustic technique.
<script type="text/javascript">
<!--
document.write('<div id="oa_widget"></div>');
document.write('<script type="text/javascript" src="https://www.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=ukri________::ffafc5e164c8b1b6510c0cff0c05b2fb&type=result"></script>');
-->
</script>
<script type="text/javascript">
<!--
document.write('<div id="oa_widget"></div>');
document.write('<script type="text/javascript" src="https://www.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=ukri________::ffafc5e164c8b1b6510c0cff0c05b2fb&type=result"></script>');
-->
</script>