Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/ ZENODOarrow_drop_down
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
ZENODO
Dataset . 2021
License: CC BY
Data sources: Datacite
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
ZENODO
Dataset . 2021
License: CC BY
Data sources: Datacite
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
ZENODO
Dataset . 2021
License: CC BY
Data sources: ZENODO
versions View all 2 versions
addClaim

Gender-associated outcomes following percutaneous coronary intervention with a third-generation, ultrathin-strut drug-eluting stent: a real world, single-center experience.

Authors: Gili, Sebastiano; Galli, Stefano; Teruzzi, Giovanni; Santagostino Baldi, Giulia; Ravagnani, Paolo; Fabbiocchi, Franco; Bartorelli, Antonio; +2 Authors

Gender-associated outcomes following percutaneous coronary intervention with a third-generation, ultrathin-strut drug-eluting stent: a real world, single-center experience.

Abstract

This record contains raw data related to the article: Gender-associated outcomes following percutaneous coronary intervention with a third-generation, ultrathin-strut drug-eluting stent: a real-world, single-center experience. ABSTRACT Introduction. In recent years the new third-generation, ultrathin bioresorbable-polymer sirolimus-eluting stent (BP-SES), characterized by some of the thinnest struts among commercially available devices (60-80 µm) and an amorphous silicon carbide coating, has been introduced for the treatment of coronary artery disease (CAD). Aim of the present study was to assess different clinical outcomes and safety of this drug-eluting stent in male and female patients in a real-world setting. Methods. The present study is a retrospective analysis including all patients treated with BP-SES between January 2017 and December 2019 at a single, high-volume center. Follow-up was performed by outpatient visit or by telephone contact. The main study outcome was target lesion failure (TLF), defined as a composite of cardiovascular death, target vessel myocardial infarction or target lesion revascularization. Results: Overall, 66 (15.9%) female and 349 (84.1%) male patients were included; women were older (median age 70 vs. 66, p=0.003) and with lower BMI (25.0 vs. 26.1, p=0.010) compared to men, with no other relevant differences in baseline characteristics. Indication for percutaneous coronary intervention (PCI) was acute coronary syndrome in 86 (20.7%) of the cases, with no significant differences between male and female patients. A total of 558 lesions were treated with BP-SES stents, 90 in women and 468 in men (1.36 vs. 1.34 lesions per patient, p=0.83); cumulative stent length (33.6 mm vs. 38.4 mm, p=0.078) and mean stent diameter (2.92 mm vs. 3.0 mm, p=0.39) did not differ in women compared to men. Technical and clinical success was achieved in all patients. Stent thrombosis (ST) occurred in 2 (0.5%) patients, both males. TLF occurred in 10 (2.9%) men and in 2 (3.0%) women after a median follow-up of 402 days, without significant differences at log-rank analysis (2.34 events per 100 patient-years in males, 2.53 in females; p=0.80). Conclusions. Ultrathin struts BP-SES showed a safe and effective option for the treatment of CAD in both women and men, with very low ST rate and favorable long-term outcomes

Keywords

PCI in women, bioresorbable-polymer, ultrathin-stent-struts, Drug-eluting stents, clinical outcomes

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    0
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
    OpenAIRE UsageCounts
    Usage byUsageCounts
    visibility views 7
    download downloads 2
  • 7
    views
    2
    downloads
    Powered byOpenAIRE UsageCounts
Powered by OpenAIRE graph
Found an issue? Give us feedback
visibility
download
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
views
OpenAIRE UsageCountsViews provided by UsageCounts
downloads
OpenAIRE UsageCountsDownloads provided by UsageCounts
0
Average
Average
Average
7
2
Related to Research communities