Downloads provided by UsageCounts
Non-targeted mass spectrometry (MS) has become an important method over the last years in the fields of metabolomics and environmental research. While more and more algorithms and workflows become available to process a large number of data sets nontargeted, there still exist few manually evaluated universal test data sets for refining and evaluating these methods. The first step of non-targeted screening, peak detection (and refinement of it) is arguably the most important step for non-targeted screening. However, the absence of a model data set makes it harder for researchers to evaluate peak detection methods. In this Data Descriptor, we provide a manually checked data set consisting of 255,000 EICs (5000 peaks randomly sampled from across 51 samples) for the evaluation on peak detection and gap filling algorithms. The data set was created from a previous real-world study, of which a subset was used to extract and manually classify ion chromatograms by three mass spectrometry experts. The data set consists of: 51 converted mass spectral files in mzML format An .RData-file containing the extracted ion chromtograms (EICs) The randomly selected subset and the original output table of MZmine in .csv-format Example .xlsx files for the classification 2 central classification tables Several tables with additional information about the sampling, chemical analysis and expert jugdement on EICs For a full description of the experiment and the data set, please read the related Data Descriptor with the title "A data set of 255000 randomly selected and manually classified extracted ion chromatograms for evaluation of peak detection methods" in Metabolites (https://www.mdpi.com/journal/metabolites; DOI: https://doi.org/10.3390/metabo10040162).
{"references": ["https://doi.org/10.1021/ac301482k", "https://doi.org/10.1186/1471-2105-11-395", "https://doi.org/10.1186/1471-2105-9-375", "https://doi.org/10.1016/j.scitotenv.2020.138388", "https://doi.org/10.1007/s00216-015-8681-7", "https://www.ebi.ac.uk/metabolights/MTBLS1455"]}
extracted ion chromatograms, EIC, peak detection, peak picking, XIC, gap filling, mass spectrometry
extracted ion chromatograms, EIC, peak detection, peak picking, XIC, gap filling, mass spectrometry
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 1 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |
| views | 64 | |
| downloads | 15 |

Views provided by UsageCounts
Downloads provided by UsageCounts