Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/ ZENODOarrow_drop_down
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
ZENODO
Dataset . 2024
License: CC BY
Data sources: ZENODO
ZENODO
Dataset . 2024
License: CC BY
Data sources: Datacite
ZENODO
Dataset . 2024
License: CC BY
Data sources: Datacite
versions View all 2 versions
addClaim

3 MeV Proton Ion beam analysis of NCA/Si anode-cathode mapping

Authors: Möller, Sören; Durdel, Axel; Streck, Luiza; Muzakka, Khoirul Faiq; Finsterbusch, Martin;

3 MeV Proton Ion beam analysis of NCA/Si anode-cathode mapping

Abstract

The dataset presents 2140 ion-beam-analysis (IBA) measurements of a NCA cathode and a Si/G anode using 2970+-20 keV protons. Figure 1 shows an example of the result. The anode and cathode foils were cycled in a full liquid electrolyte cell for 340 cycles and analysed in the state-of-charge =0. The cell consisted of 20 cathode and 20 anode layer from which 2 cathode and 2 anode layers from the top (KT, AT) and middle (AM, KM) were extracted for IBA. For practical reasons each of the 110x80 mm² foils was cut into 9 equal parts. Four detectors acquire the data simultaneously for RBS, NRA, PIGE, and PIXE. The description of the end-station and detectors can be found here: https://doi.org/10.3390/instruments5010010. Each point on the sample consists of 4 files, four detector spectra. The filename consists of the sample name, three positions in units of nm (X, Y, Z), a rotation in units of µ° followed by an underscore ( _ ) and the type of data contained in the file (RBS, NRA, PIXE, PIGE, or Meta). Only X and Z positions are relevant in this case as indicated in the attached figure. The RBS, NRA, and PIGE detector files contain a header specifying the dead- and live-time followed by two columns. The first column represents the digital channel of the detector. The second column represents the counts acquired in this channel. This format is readable as ASCI by SimNRA7. SimNRA 7 reference evaluations are included in the dataset. The PIXE file contains the number of channels in the first row/header and only the counts in the subsequent rows. The channel is given by the row number. This format is readable by GUPIXWIN3. Example GUPIXWIN files are included The channels of the detector files can be re-calculated using a calibration shown in the following table 1. Certain drifts in the calibrations are possible, but should be limited to below 2% of the given value. All points are integrated to the same ion dose of 2 µC. This corresponds to a Particle*Sr of about 5.0E+10 (RBS detector), 5.4E+11 (NRA). Table 1: Detector calbration enabling a recalculation of channels to energy. Units are in keV Detector Linear (multiply with channel) Offset (add to first result) RBS 2.8 10 NRA 5.5 10 PIXE 0.184 1.5 PIGE 0.85 0

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    0
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
0
Average
Average
Average