Downloads provided by UsageCounts
doi: 10.1109/19.192281
Results of a realization of the ohm and farad using the US National Bureau of Standards (NBS) calculable capacitor and associated apparatus are reported. The results show that both the NBS representation of the ohm and the NBS representation of the farad are changing with time, Omega /sub NBS/ at the rate of -0.054 p.p.m./year and F/sub NBS/ at the rate of 0.010 p.p.m./year. The realization of the ohm is of particular significance because of its role in assigning an SI value to the quantized Hall resistance. The estimated uncertainty of the ohm realization is 0.022 p.p.m. (1 sigma ), while the estimated uncertainty of the farad realization is 0.014 p.p.m. (1 sigma ). >
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 35 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Top 10% |
| views | 2 | |
| downloads | 9 |

Views provided by UsageCounts
Downloads provided by UsageCounts