doi: 10.4271/2006-01-0868
<div class="htmlview paragraph">A gravimetric particulate measurement system, which extracts samples isokinetically from raw exhaust, is presented to quantify the particulate mass stored in diesel particulate filters. The purpose of this measurement system is to facilitate the study of wall-flow filter behavior at different particulate load levels. Within this paper, the design considerations for the particulate measurement system are detailed and its operation is described. The accuracy of the measurement is examined through a theoretical error analysis and direct experimental comparison to the differential weight of a diesel particulate filter. Experimental results are also presented to validate the ability of the system to maintain the isokinetic sampling condition.</div>
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 4 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |