Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/ Journal of the Socie...arrow_drop_down
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
Journal of the Society of Materials Science Japan
Article . 2002 . Peer-reviewed
Data sources: Crossref
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
versions View all 1 versions
addClaim

A Study on the Incident Beam Methods of .OMEGA. Assembly X-Ray Stress Measurement Using a Position Sensitive Proportional Counter as a Detector.

PSPCを用いた並傾法X線応力測定におけるX線入射法に関する研究
Authors: Toru GOTO; Yu GONG;

A Study on the Incident Beam Methods of .OMEGA. Assembly X-Ray Stress Measurement Using a Position Sensitive Proportional Counter as a Detector.

Abstract

Recently, the position sensitive proportional counter (PSPC) has been becoming popular as a detector for X-ray stress measurement. However, little information is available in the literature regarding the effects of specimen mis-setting and/or collimator misalignment on the stress measurement. This is because many factors such as the stress and the X-ray diffraction broadening of specimen, the X-ray focus size, the dimensions of the collimator, the PSPC and the goniometer, et al., are complicatedly related to the effects of specimen mis-setting and/or collimator mis-alignment. The authors have presented a model of Ω assembly X-ray stress measurement using a PSPC as the detector enabling us to simulate the stress measurement under the various conditions including specimen mis-setting and/or collimator misalignment. And they have successfully reported on their effects to the stress measurement.In this paper, the incident beam methods with and without focusing are discussed using the model and the simulation method of the Ω assembly X-ray stress measurement from the view of the collimator intrinsic stress and the stress errors caused by specimen mis-setting and collimator/slit misalignment. The incident beams treated are point focus beam, collimated beam and parallel beam. As the conclusions obtained by this study, it was found that the parallel beam method gives smaller intrinsic stress than the other incident beams do. It was also found that it is possible to reduce the intrinsic stress using the focusing method for the point focused beam and collimated beam. It was demonstrated that the focusing method with the point focused beam and/or collimated beam makes the stress measurement sensitive to the specimen mis-setting but not to the collimator/slit misalignment. On the other hand, the defocusing method is sensitive to the collimator/slit misalignment but not to the specimen mis-setting.

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    0
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
0
Average
Average
Average
gold