This paper addresses the fault tolerant estimation problem. Fault tolerance is defined with respect to a given estimation objective, namely a given functional of the system state should remain observable when sensor failures occur. Three criteria, which evaluate the system fault tolerance with respect to sensor failures when a reconfiguration strategy is used, are introduced, and it is shown that they can be used to define maintenance policies. A ship boiler example is used for illustration.
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 3 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |