The illuminance measurement method for a comparative evaluation of two light pipes is described in the paper. Two commercially available light pipes of similar dimensions were evaluated for light transmittance. Measurement and data processing methodology was completed for the comparison of the light pipe efficiency. Results of continual one minute intervals measurements are presented for three month monitoring.