image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao IEEE Transactions on...arrow_drop_down
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
IEEE Transactions on Power Delivery
Article . 2017 . Peer-reviewed
License: IEEE Open Access
Data sources: Crossref
versions View all 1 versions
addClaim

Resonance Analysis and Faulty Feeder Identification of High-Impedance Faults in a Resonant Grounding System

Authors: Yongduan Xue; Xiaoru Chen; Huamao Song; Bingyin Xu;

Resonance Analysis and Faulty Feeder Identification of High-Impedance Faults in a Resonant Grounding System

Abstract

High-impedance faults (HIF) occur frequently in resonant grounding systems and are difficult to detect. Thus, an effective HIF feeder identification technology is urgently needed. This paper establishes an HIF equivalent circuit in a resonant grounding system. The change rule of transient zero-sequence voltage, transient zero-sequence currents, and their projection components with respect to the transient zero-sequence voltage of the bus are analyzed in both underdamping and overdamping resonance conditions. Furthermore, the variation ranges of the resonant frequency, the magnitude, the attenuation factor, and other parameters are specified in detail. The magnitude and phase relationships of zero-sequence currents among the faulty feeder, healthy feeders, Petersen coil, and fault points, as well as the relationships between their projection components and quadrature components with respect to the transient zero-sequence voltage are analyzed and compared. A novel faulty feeder identification method based on a comparison of the magnitude and polarity of the transient zero-sequence current's projection component is proposed. The accuracy of the transient characteristics and the feasibility of the proposed method are verified by simulations and field data.

Related Organizations
  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    62
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Top 1%
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 10%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Top 10%
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
62
Top 1%
Top 10%
Top 10%
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!