The objective of this paper is the implementation through numerical modelling of Halbach permanent magnets for the determination of the optimum magnetization directions in order to obtain a uniform magnetic field around the set of Halbach permanent magnets. For this study the magnetic induction distribution, magnetic field intensity and current density for the studied magnets are compared. From the different types of Halbach arrays, the linear array represents the subject of this study.