A New Finger Joint Prosthesis

Authors: Fumio Fukumura; Michael J. Sarrasin; Hiroaki Harasaki; Robert L. Whalen; M. A. Bowen;

A New Finger Joint Prosthesis

Abstract

A new finger joint prosthesis is being developed for the proximal and distal interphalangeal positions. Currently available "joint spacer" prostheses provide relief from pain and cosmetic improvement, but relatively poor long-term function. The new prosthesis employs a mechanical hinge at the joint. It is fabricated from titanium alloy (6A14V). The hinge mechanism avoids direct metal to metal contact by using high density polyethylene bearings. In vitro tests of the hinge mechanism have passed 75 million cycles of continuous flexure without failure (n = 12). The hinge also incorporates a mechanical limit stop to prevent hyperextension. The hinge mechanism is enclosed in a sealed elastomeric jacket that isolates the hinge from connective tissue ingrowth. The jacket, equivalent to an artificial synovial membrane, has an integrally textured exterior surface designed to promote tissue attachment to the implant to stabilize tissue capsule formation around the joint. To test the in vivo efficacy of the new design, a series of 12 devices were implanted in the knee joint position of adult rabbits. A jacketed prosthesis was implanted on one side, whereas 2 weeks later an unjacketed control was implanted contralaterally. The animals then were maintained for an 8 week period. At sacrifice, the implants were removed, and the response of the surrounding tissues was studied histologically. At the time of implantation, the range of motion of the joints was approximately 100-105 degrees. There was a progressive loss in range of motion observed in both groups. The fibrous tissue capsule around the jacketed implants, however, was significantly reduced in thickness compared with the controls (mean thickness, 1.5 mm vs. 4.5 mm).(ABSTRACT TRUNCATED AT 250 WORDS)

Keywords

Knee Joint, Surface Properties, Joint Prosthesis, Prosthesis Design, Models, Biological, Biomechanical Phenomena, Finger Joint, Materials Testing, Microscopy, Electron, Scanning, Animals, Rabbits, Range of Motion, Articular

  • BIP!
    Impact byBIP!
    citations
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    4
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
citations
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
4
Average
Average
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!