publication . Article . 2013

High-voltage pixel detectors in commercial CMOS technologies for ATLAS, CLIC and Mu3e experiments

Peric,I et al.;
Open Access English
  • Published: 01 Jan 2013
  • Publisher: Nucl. Instrum. Methods Phys. Res., A
Abstract
High-voltage particle detectors in commercial CMOS technologies are a detector family that allows implementation of low-cost, thin and radiation-tolerant detectors with a high time resolution. In the R/D phase of the development, a radiation tolerance of 1015 neq=cm2 , nearly 100% detection efficiency and a spatial resolution of about 3 μm were demonstrated. Since 2011 the HV detectors have first applications: the technology is presently the main option for the pixel detector of the planned Mu3e experiment at PSI (Switzerland). Several prototype sensors have been designed in a standard 180 nm HV CMOS process and successfully tested. Thanks to its high radiation ...
Subjects
arXiv: Physics::Instrumentation and DetectorsHigh Energy Physics::Experiment
free text keywords: Detectors and Experimental Techniques, Advanced infrastructures for detector R&D [9], Precision Pixel Detectors [9.3]
Funded by
EC| AIDA
Project
AIDA
Advanced European Infrastructures for Detectors at Accelerators
  • Funder: European Commission (EC)
  • Project Code: 262025
  • Funding stream: FP7 | SP4 | INFRA
Download from