Prevalence and Associated Factors in Self-Monitoring of Blood Glucose in Noninsulin-treated Type 2 Diabetes Patients in the Valencia Community, Spain

Article Spanish OPEN
Cano-Blanquer, Diego; Cervera-Casino, Pedro; Peiró-Moreno, Salvador; Mateu-García, Mónica; Barreda-Aznar, Amparo;
(2013)
  • Publisher: Ministerio de Sanidad Servicios Sociales e Igualdad
  • Subject: Utilización de medicamentos | Spain | Type 2 | Drug utilization | Antidiabéticos orales | Blood Glucose Self-Monitoring | Diabetes Mellitus tipo 2 | Diabetes Mellitus | Automonitorización de glucosa en sangre | Estudios transversales | Hypoglycemic Agents | Cross-Sectional Studies

Fundamentos: La utilidad de la automonitorización de la glucemia (AMGS) en pacientes con diabetes tipo 2 (DM2) no tratados con insulina (NTI) es objeto de controversia. Los objetivos de este trabajo son describir la prevalencia de AMGS en sujetos con DM2 NTI en la Comun... View more
  • References (30)
    30 references, page 1 of 3

    11. Coster S, Gulliford MC, Seed PT, Powrie JK, Swaminathan R. Selfmonitoring in type 2 diabetes mellitus: A meta-analysis. Diabet Med. 2000; 17:755-761.

    12. Towfigh A, Romanova M, Weinreb JE, Munjas B, Suttorp MJ, Zhou A, et al. Self-monitoring of blood glucose levels in patients with type 2 diabetes mellitus not taking insulin: a meta-analysis. Am J Manag Care. 2008;14:468-75.

    13. Davidson MB. Evaluation of self monitoring of blood glucose in non-insulin-treated diabetic patients by randomized controlled trials: little bang for the buck. Rev Recent Clin Trials. 2010;5:138-42.

    14. Clar C, Barnard K, Cummins E, Royle P, Waugh N; Aberdeen Health Technology Assessment Group. Selfmonitoring of blood glucose in type 2 diabetes: systematic review. Health Technol Assess. 2010;14:1-140.

    15. Welschen LM, Bloemendal E, Nijpels G, Dekker JM, Heine RJ, Stalman WA, et al. Self-monitoring of blood glucose in patients with type 2 diabetes who are not using insulin. Cochrane Database Syst Rev. 2005 Apr 18;(2):CD005060.

    16. Clua Espuny JL, Puig Junoy J, Queralt Tomás ML, Palau Galindo A. Análisis coste-efectividad de la automonitorizacion de la glucosa sanguinea en diabeticos tipo 2. Gac Sanit. 2000;14:442-8.

    17. Simon J, Gray A, Clarke P, Wade A, Neil A, Farmer A; Diabetes Glycaemic Education and Monitoring Trial Group. Cost effectiveness of self monitoring of blood glucose in patients with non-insulin treated type 2 diabetes: economic evaluation of data from the DiGEM trial. BMJ. 2008;336:1177-80.

    23. Gomes T, Juurlink DN, Shah BR, Paterson JM, Mamdani MM. Blood glucose test strips: options to reduce usage. CMAJ. 2010;182:35-8.

    24. Belsey JD, Pittard JB, Rao S, Urdahl H, Jameson K, Dixon T. Self blood glucosemonitoring in type 2 diabetes. A financial impact analysis based on UK primary care. Int J Clin Pract. 2009;63:439-48.

    25. Gulliford M, Latinovic R. Variations in glucose self-monitoring during oral hypoglycaemic therapy in primary care. Diabet Med. 2004;21:685-90.

  • Metrics