Modo de registro e efeitos da modulação em frequências nos limiares de resposta auditiva de estado estável

Article English OPEN
Jalaei, Bahram; Shaabani, Moslem; Zakaria, Mohd Normani;
(2017)
  • Publisher: Associação Brasileira de Otorrinolaringologia e Cirurgia Cervicofacial
  • Subject: Contralateral recording | Hearing threshold | Resposta auditiva de estado estável | Registro contralateral | Auditory steady state response | Registro ipsilateral | Ipsilateral recording | Limiar auditivo

Abstract Introduction The performance of auditory steady state response (ASSR) in threshold testing when recorded ipsilaterally and contralaterally, as well as at low and high modulation frequencies (MFs), has not been systematically studied. Objective To verify the i... View more
  • References (24)
    24 references, page 1 of 3

    1. Kuwada S, Anderson J, Batra R. Sources of the scalp-recorded amplitude-modulation following response. J Am Acad Audiol. 2002;13:188--204.

    2. Batra R, Kuwada S, Stanford TR. Temporal coding of envelopes and their interaural delays in the inferior colliculus of the unanaesthetized rabbit. J Neurophysiol. 1989;61:257--68.

    3. Creutzfeldt OD, Hellweg FC, Schreiner C. Thalamocortical transformation of responses to complex auditory stimuli. Exp Brain Res. 1980;39:87--104.

    4. Herdman AT, Lins O, Van Room P. Intracerebral sources of human auditory steady-state responses. Brain Topogr. 2002;15:69--86.

    5. Tomlin D, Rance G, Graydon K. A comparison of 40 Hz auditory steady-state response (ASSR) and cortical auditory evoked potential (CAEP) thresholds in awake adult subjects. Int J Audiol. 2006;45:580--8.

    6. Van Maanen A, Stapells DR. Comparison of multiple auditory steady-state responses (80 vs 40 Hz) and slow cortical potentials for threshold estimation in hearing-impaired adults. Int J Audiol. 2005;44:613--24.

    7. Van Maanen A, Stapells DR. Normal multiple auditory steadystate response thresholds to air-conducted stimuli in infants. J Am Acad Audiol. 2009;20:196--207.

    8. Kaf WA, Danesh AA. Air-conduction auditory steady-state response: comparison of interchannel recording using two modulation frequencies. J Am Acad Audiol. 2008;19:696--707.

    9. Vander Werff KR, Brown CJ. Effect of audiometric configuration on threshold and suprathreshold auditory steady-state responses. Ear Hear. 2005;26:310--26.

    10. Dau T, Wagner O, Mellert V, Kollmeier B. Auditory brainstem responses with optimized chirp signals compensating basilar membrane dispersion. J Acoust Soc Am. 2000;107:1530--40.

  • Related Organizations (1)
  • Metrics
Share - Bookmark