publication . Other literature type . Article . 2016

Ambient Conditions Effects On Performance Of Gas Turbine Cogeneration Power Plants

Necmi Ozdemir*;
Open Access
  • Published: 20 Dec 2016
  • Publisher: Zenodo
Abstract
In this study, the performances of a simple and an air preheated cogeneration cycles in ambient conditions are compared with each other. A computer program written by the author in FORTRAN codes is used for the calculation of the enthalpy and entropy values of the streams, Exergy analysis is done and compared for the simple and the air preheated cogeneration cycles for different ambient conditions. The two cogeneration cycles are evaluated in terms of heat powers and electric, electrical to heat ratio, heat exergy, and exergetic efficiency with respect to humidity, temperature, and atmospheric pressure. The simple cycle is better in obtaining high heat rate and ...
Subjects
free text keywords: Cogeneration, environment, efficiency
Download fromView all 2 versions
Zenodo
Other literature type . 2016
Provider: Datacite
ZENODO
Article . 2016
Provider: ZENODO
Powered by OpenAIRE Research Graph