Abstract
Concentrated Solar Power (CSP) projects require accurate assessment and monitoring of the available direct beam resource. To this end, ground measurements on site are inexpendable. Pyrheliometers with thermopile sensors as specied in [ISO 9060] are the standard instruments for eld measurements of direct beam irradiance. During long-term deployment however, their comparatively high accuracy can only be maintained if the window through which the direct beam enters the instrument is cleaned frequently [Geuder and Quaschning, 2006]. In the case of long-term solar resource assessments on site this can pose a problem in terms of logistics and maintenance costs. This i...