Anterior Communicating Artery Aneurysm Surgery

Which Is The Most Appropriate Head Position?
Authors: Ozdemir M; Comert A; Ugur HC; Kahilogullari G; Tubbs RS; Egemen N;

Anterior Communicating Artery Aneurysm Surgery

Abstract

Head positioning and the degree of rotation for anterior communicating artery aneurysm surgery is controversial. With this anatomic study, we aimed to give a broad description of head positioning for various aneurysm dome projections. In addition, with the use of a corrosion-cast technique, a three-dimensional arterial tree was demonstrated, an anterior communicating artery region aneurysm model was prepared, and pictures were taken at various angles. According to our observations, 30-degree head rotation was found to be the most suitable position for the anterior and superior projected aneurysms. For posterior projection, aneurysm neck was best viewed with 15-degree head rotation. Aneurysms projecting inferiorly necessitated the greatest rotation at 45 degrees. Each aneurysm dome projection of the anterior communicating artery aneurysm should be individually considered, and the head position should be adjusted accordingly. The use of appropriate head positions during surgery will prevent the development of postoperative ischemic complications and will increase the success of surgery by preventing unnecessary tissue manipulation.

Keywords

Male, Rotation, Intracranial Aneurysm, Middle Aged, Aged; Brain Ischemia/prevention & control; Cadaver; Circle of Willis/pathology; Head/*anatomy & histology; Humans; Imaging, Three-Dimensional/methods; Intracranial Aneurysm/*surgery; Male; Middle Aged; *Patient Positioning; Photography/methods; Postoperative Complications/prevention & control; Replica Techniques; Rotation, Patient Positioning, Brain Ischemia, Imaging, Three-Dimensional, Postoperative Complications, Cadaver, Photography, Circle of Willis, Humans, Replica Techniques, Head, Aged

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    4
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
4
Average
Average
Average
Green