MATHEMATIC SIMULATION OF TRANSIENT PROCESS IN A.C. – SYSTEM “ELECTRIC TRACTION NETWORK – LOCOMOTIVE” 1. SWITCH ON LOCOMOTIVE’S POWER CONVERTER IN “FREE PLAY” MODE; PARAMETERS ESTIMATION

Article English OPEN
T. M. Mishchenko ; A. I. Kiiko (2010)
  • Publisher: Dnipropetrovsk National University of Railway Transport named after Academician V. Lazaryan
  • Journal: Nauka ta Progres Transportu (issn: 2307-3489, eissn: 2307-3489)
  • Subject: mathematical model | traction substation | parameters of traction mains | electric locomotive | transformer | Transportation engineering | TA1001-1280

In the article the electric circuit of substitution and mathematical model of the system of alternating current «traction substation − traction mains − electric locomotive DS 3» at switching its power transformer on in the idle mode are presented. Numerical determinations of parameters of traction substation, rails, contact network and transformer are executed; in so doing a special attention is paid to the estimation of dispersion inductance for the primary winding of transformer.
Share - Bookmark