Structural Glass Systems under Fire: Overview of Design Issues, Experimental Research, and Developments

Review, Article English OPEN
Bedon, Chiara (2017)
  • Publisher: Hindawi
  • Journal: Advances in Civil Engineering (issn: 1687-8086, eissn: 1687-8094)
  • Related identifiers: doi: 10.1155/2017/2120570
  • Subject: TA1-2040 | Engineering (General). Civil engineering (General) | structural glass; fire loading; material properties; experiments; Finite Element numerical modelling | Article Subject

Architectural design concepts incorporating glass beams, panels, or generally load-carrying elements and stiffeners for buildings, claddings, windows, and partitions are largely considered in modern high-rise constructions. A multitude of aspects, including motivations ... View more
  • References (84)
    84 references, page 1 of 9

    [1] M. Haldimann, A. Luible, and M. Overend, Structural Use of Glass, International Association for Bridge and Structural Engineering (IABSE), Zurich, Switzerland, 2008, ISBN 978-3- 85748-119-2.

    [2] M. Feldmann, R. Kasper, B. Abeln et al., Guidance for European Structural Design of Glass Components-Support to the Implementation, Harmonization and Further Development of the Eurocodes, Report EUR 26439, P. Dimova and D. Feldmann, Eds., Joint Research Centre-Institute for the Protection and Security of the Citizen, Brussels, Belgium, 2014.

    [3] M. Santarsiero, C. Louter, and A. Nussbaumer, “Laminated connections for structural glass applications under shear loading at di-erent temperatures and strain rates,” Construction and Building Materials, vol. 128, pp. 214-237, 2016.

    [4] J. Belis, C. Bedon, C. Louter, C. Amadio, and R. Van Impe, “Experimental and analytical assessment of lateral torsional buckling of laminated glass beams,” Engineering Structures, vol. 51, pp. 295-305, 2013.

    [5] S. Jordão, M. Pinho, J. P. Martin, A. Santiago, and L. C. Neves, “Behaviour of laminated glass beams reinforced with pre-stressed cables,” Steel Construction, vol. 7, no. 3, pp. 204-207, 2014.

    [6] C. Pascual, J. Montali, and M. Overend, “Adhesively-bonded GFRP-glass sandwich components for structurally eMcient glazing applications,” Composite Structures, vol. 160, pp. 560-573, 2017.

    [7] P. A. Hooper, R. A. M. Sukhram, B. R. K. Blackman, and J. P. Dear, “On the blast resistance of laminated glass,” International Journal of Solids and Structures, vol. 49, no. 6, pp. 899-918, 2012.

    [8] X. Zhang, H. Hao, and G. Ma, “Parametric study of laminated glass window response to blast loads,” Engineering Structures, vol. 56, pp. 1707-1717, 2013.

    [9] X. Zhang and C. Bedon, “Vulnerability and protection of glass windows and facades under blast: experiments, methods and current trends,” International Journal of Structural Glass and Advanced Materials Research, vol. 1, no. 1, 14 pages, 2017.

    [10] R. A. Behr, A. Belarbi, and A. T. Brown, “Seismic performance of architectural glass in a storefront wall system,” Earthquake Spectra, vol. 11, no. 3, pp. 367-391, 1995.

  • Metrics
    No metrics available
Share - Bookmark