Computed tomography-guided biopsies in children: accuracy, efficiency and dose usage

Thomas Klingebiel; Nagy N.N. Naguib; Katrin Eichler; Axel Thalhammer; Tatjana Gruber-Rouh; Martin Beeres; Thomas J. Vogl; Nour-Eldin A. Nour-Eldin;
Open Access English
  • Published: 06 Jan 2017 Journal: Italian Journal of Pediatrics, volume 43, issue 1 (issn: 1824-7288, Copyright policy)
  • Publisher: Springer Nature
Abstract
Background Computed-tomography-guided interventions are attractive for tissue sampling of paediatric tumor lesions; however, it comes with exposure to ionizing radiation. The aim of this study was to analyse the radiation dose, accuracy and speed of CT-guided interventions in paediatric patient cohort. Methods We retrospectively reviewed CT-guided interventions over a 10 -year period in 65 children. The intervention site consisted of bones in 38, chest (lung) in 15 and abdomen (liver, lymph nodes) in 12 cases. Radiation dose and duration of the procedures were analysed. The statistical analysis was performed using dedicated statistical software (BiAS 8.3.6 softw...
Subjects
free text keywords: Research, Children, CT-guidance, Tissue sampling, Image-Guided Biopsy, Medicine, business.industry, business, Ionizing radiation, Paediatric patients, Biopsy, medicine.diagnostic_test, Computed tomography, Cohort, Radiology, medicine.medical_specialty, Retrospective cohort study
Related Organizations
25 references, page 1 of 2

Honnef, D, Wildberger, JE, Schubert, H, Hohl, C, Günther, RW, Mahnken, A. CT-guided interventions in children. Röfo. 2007; 179 (6): 605-12 [PubMed]

Skrzynski, MC, Biermann, JS, Montag, A, Simon, MA. Diagnostic accuracy and charge-savings of outpatient core needle biopsy compared with open biopsy of musculoskeletal tumors. J Bone Joint Surg Am. 1996; 78 (5): 644-9 [OpenAIRE] [PubMed] [DOI]

Lachar, WA, Shahab, I, Saad, AJ. Accuracy and cost-effectiveness of core needle biopsy in the evaluation of suspected lymphoma: a study of 101 cases. Arch Pathol Lab Med. 2007; 131 (7): 1033-9 [PubMed]

Issakov, J, Flusser, G, Kollender, Y, Merimsky, O, Lifschitz-Mercer, B, Meller, I. Computed tomography-guided core needle biopsy for bone and soft tissue tumors. Isr Med Assoc J. 2003; 5 (1): 28-30 [PubMed]

Metz, T, Heider, A, Vellody, R, Jarboe, MD, Gemmete, JJ, Grove, JJ. Image-guided percutaneous core needle biopsy of soft-tissue masses in the pediatric population. Pediatr Radiol. 2016; 46 (8): 1173-8 [OpenAIRE] [PubMed] [DOI]

Larson, DB, Molvin, LZ, Wang, J, Chan, FP, Newman, B, Fleischmann, D. Pediatric CT quality management and improvement program. Pediatr Radiol. 2014; 44 (Suppl 3): 519-24 [OpenAIRE] [PubMed] [DOI]

Omary, RA, Bettmann, MA, Cardella, JF, Bakal, CW, Schwartzberg, MS, Sacks, D. Quality improvement guidelines for the reporting and archiving of interventional radiology procedures. J Vasc Interv Radiol. 2003; 14 (9 Pt 2): S293-5 [PubMed] [DOI]

Sacks, D, McClenny, TE, Cardella, JF, Lewis, CA. Society of Interventional Radiology clinical practice guidelines. J Vasc Interv Radiol. 2003; 14 (9 Pt 2): S199-202 [PubMed] [DOI]

Yu, MC, Lee, F, Huang, WH, Hsueh, S. Percutaneous ultrasound-guided renal biopsy in children: The need for renal biopsy in pediatric patients with persistent asymptomatic microscopic hematuria. Biomed J. 2014; 37 (6): 391-7 [OpenAIRE] [PubMed] [DOI]

Zangos, S, Müller, C, Mayer, F, Naguib, NN, Nour-Eldin, NE, Hansmann, ML. Retrospective 5-year analysis of MR-guided biopsies in a low-field MR system. Röfo. 2009; 181 (7): 658-63 [PubMed]

Matos, H, Noruegas, MJ, Gonçalves, I, Sanches, C. Effectiveness and safety of ultrasound-guided percutaneous liver biopsy in children. Pediatr Radiol. 2012; 42 (11): 1322-5 [OpenAIRE] [PubMed] [DOI]

Schell, B, Eichler, K, Mack, MG, Müller, C, Kerl, JM, Czerny, C. Robot-assisted biopsies in a high-field MRI system - first clinical results. Röfo. 2012; 184 (1): 42-7 [PubMed]

Palestrant, AM. Comprehensive approach to CT-guided procedures with a hand-held guidance device. Radiology. 1990; 174 (1): 270-2 [OpenAIRE] [PubMed] [DOI]

14.Ritter M, Rassweiler MC, Häcker A, Michel MS. Laser-guided percutaneous kidney access with the Uro Dyna-CT: first experience of three-dimensional puncture planning with an ex vivo model. World J Urol. 2013;31(5):1147-51.

15.Mahnken AH, Wilhelm KE, Ricke J. CT- and MRI-guided interventions in radiology. Germany: Springer-Verlag GmbH; 2013.

25 references, page 1 of 2
Any information missing or wrong?Report an Issue