publication . Article . Preprint . 2013

Results on damage induced by high-energy protons in LYSO calorimeter crystals

D. Luckey; Maurice Glaser; Francesca Nessi-Tedaldi; Rainer Wallny; Milena Quittnat; Günther Dissertori; Felicitas Pauss;
Open Access
  • Published: 16 Sep 2013 Journal: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, volume 745, pages 1-6 (issn: 0168-9002, Copyright policy)
  • Publisher: Elsevier BV
Abstract
Comment: 10 pages, 9 figures, submitted to Elsevier for publication in Nucl. Instr. Meth. in Phys. Research A
Subjects
arXiv: Physics::Instrumentation and DetectorsPhysics::Medical PhysicsNuclear ExperimentHigh Energy Physics::ExperimentAstrophysics::High Energy Astrophysical Phenomena
free text keywords: Nuclear and High Energy Physics, Instrumentation, Crystal, Damage, Detectors and Experimental Techniques, Improvement and equipment of irradiation and test beam lines [8], Qualification of components and common database [8.4], Physics - Instrumentation and Detectors, Orthosilicate, chemistry.chemical_compound, chemistry, Fluence, Physics, Calorimeter, Proton, Hadron, Scintillator, Lyso-, Large Hadron Collider, Nuclear physics
Funded by
SNSF| Physics at 13-14 TeV with the CMS experiment at the LHC
Project
  • Funder: Swiss National Science Foundation (SNSF)
  • Project Code: 200020_149870
  • Funding stream: Project funding | Project funding (Div. I-III)
,
EC| AIDA
Project
AIDA
Advanced European Infrastructures for Detectors at Accelerators
  • Funder: European Commission (EC)
  • Project Code: 262025
  • Funding stream: FP7 | SP4 | INFRA
28 references, page 1 of 2

[1] M. Huhtinen, P. Lecomte, D. Luckey, F. Nessi-Tedaldi, F. Pauss, Nucl. Instr. and Meth. A 545 (2005) 63-87.

[2] P. Lecomte, D. Luckey, F. Nessi-Tedaldi, F. Pauss, Nucl. Instr. and Meth. A 564 (2006) 164-168.

[3] P. Lecomte, D. Luckey, F. Nessi-Tedaldi, F. Pauss, D. Renker, Nucl. Instr. and Meth. A 587 (2008) 266 - 271.

[4] G. Dissertori, D. Luckey, F. Nessi-Tedaldi, F. Pauss, R. Wallny, R. Spikings, R. Van der Lelij, G. Arnau Izquierdo, Nucl. Instr. and Meth. A 684 (2012) 57-62.

[5] G. Dissertori, P. Lecomte, D. Luckey, F. Nessi-Tedaldi, F. Pauss, Th. Otto, S. Roesler, Ch. Urscheler, Nucl. Instr. and Meth. A 622 (2010) 41-48.

[6] The CMS Electromagnetic Calorimeter Group, P. Adzic et al., 2010 JINST 5 P03010.

[7] F. Nessi-Tedaldi, “Response evolution of the CMS ECAL and R&D studies for electromagnetic calorimetry at the High-Luminosity LHC”, Proc. IEEE NSS Symposium 2012 (Anaheim, USA), paper N35-4 and CMS Conference Report CR-2012/296 (CERN, Geneva, Switzerland).

[8] F. Nessi-Tedaldi, “Studies of the effect of charged hadrons on Lead Tungstate crystals”, J. Physics: Conf. Series 160 (2009) 012013.

[9] A.S.Iljinov, M. V. Mebel, C. Guaraldo, V. Lucherini, E. De Sanctis, N. Bianchi, P. Levi Sandri, V. Muccifora, E. Polli, A. R. Reolon, and P. Rossi, S. Lo Nigro, Phys. Rev. C 39 (1989) 1420-1424.

[10] M. Kobayashi et al., Nucl. Instr. Meth. 206 (1983) 107-117.

[11] F. Nessi-Tedaldi, Int. J. Mod. Phys. A20 (2005) 3826-3829.

[12] A. Barysevich, V. Dormenev, A. Fedorov, M. Glaser, M. Kobayashi, M. Korjik, F. Maas, V. Mechinski, R. Rusack, A. Singovski, R. Zoueyski, Nucl. Instr. and Meth. A 701(2013) 231-234.

[13] A. H. Gomes et al., Mat. Res. Bull. 4 (1969) 643.

[14] C. Melcher US Patent, No. 4958080, 1990.

[15] C. Melcher and J. Schweitzer, IEEE TNS 39 (1992) 502-505.

28 references, page 1 of 2
Any information missing or wrong?Report an Issue