Seismic and Power Generation Performance of U-Shaped Steel Connected PV-Shear Wall under Lateral Cyclic Loading

Article English OPEN
Hongmei Zhang; Jinzhi Dong; Yuanfeng Duan; Xilin Lu; Jinqing Peng;
(2014)

BIPV is now widely used in office and residential buildings, but its seismic performance still remained vague especially when the photovoltaic (PV) modules are installed on high-rise building facades. A new form of reinforced concrete shear wall integrated with photovol... View more
  • References (32)
    32 references, page 1 of 4

    Diner, F.. The analysis on photovoltaic electricity generation status, potential and policies of the leading countries in solar energy. Renewable and Sustainable Energy Reviews. 2011; 15 (1): 713-720

    Peng, J., Lu, L., Yang, H.. An experimental study of the thermal performance of a novel photovoltaic double-skin facade in Hong Kong. Solar Energy. 2013; 97: 293-304

    Barkaszi, S., Dunlop, J.. Discussion of strategies for mounting photovoltaic arrays on rooftops. : 333-338

    Mekhilef, S., Saidur, R., Safari, A.. A review on solar energy use in industries. Renewable and Sustainable Energy Reviews. 2011; 15 (4): 1777-1790

    Braun, P., Rüther, R.. The role of grid-connected, building-integrated photovoltaic generation in commercial building energy and power loads in a warm and sunny climate. Energy Conversion and Management. 2010; 51 (12): 2457-2466

    Azadian, F., Radzi, M. A. M.. A general approach toward building integrated photovoltaic systems and its implementation barriers: a review. Renewable and Sustainable Energy Reviews. 2013; 22: 527-538

    Prasad, D. K., Snow, M.. Designing with Solar Power: A Source Book for Building Integrated Photovoltaics (BiPV). 2005

    Delisle, V., Kummert, M.. A novel approach to compare building-integrated photovoltaics/thermal air collectors to side-by-side PV modules and solar thermal collectors. Solar Energy. 2014; 100: 50-65

    Shameri, M. A., Alghoul, M. A., Sopian, K., Zain, M. F. M., Elayeb, O.. Perspectives of double skin façade systems in buildings and energy saving. Renewable and Sustainable Energy Reviews. 2011; 15 (3): 1468-1475

    National building standard design Atlas, null. Building solar photovoltaic systems design and installation (10J908-5).

  • Metrics
Share - Bookmark