Depth of interaction and bias voltage depenence of the spectral response in a pixellated CdTe detector operating in time-over-threshold mode subjected to monochromatic X-rays

Article English OPEN
Fröjdh, E. ; Fröjdh, C. ; Gimenez, E.N. ; Maneuski, D. ; Marchal, J. ; Norlin, B. ; O'Shea, V. ; Stewart, G. ; Wilhelm, H. ; Zain, R.Modh ; Thungström, G. (2012)

High stopping power is one of the most important figures of merit for X-ray detectors. CdTe is a promising material but suffers from: material defects, non-ideal charge transport and long range X-ray fluorescence. Those factors reduce the image quality and deteriorate spectral information. In this project we used a monochromatic pencil beam collimated through a 20μm pinhole to measure the detector spectral response in dependance on the depth of interaction. The sensor was a 1mm thick CdTe detector with a pixel pitch of 110μm, bump bonded to a Timepix readout chip operating in Time-Over-Threshold mode. The measurements were carried out at the Extreme Conditions beamline I15 of the Diamond Light Source. The beam was entering the sensor at an angle of \texttildelow20 degrees to the surface and then passed through \texttildelow25 pixels before leaving through the bottom of the sensor. The photon energy was tuned to 77keV giving a variation in the beam intensity of about three orders of magnitude along the beam path. Spectra in Time-over-Threshold (ToT) mode were recorded showing each individual interaction. The bias voltage was varied between -30V and -300V to investigate how the electric field affected the spectral information. For this setup it is worth noticing the large impact of fluorescence. At -300V the photo peak and escape peak are of similar height. For high bias voltages the spectra remains clear throughout the whole depth but for lower voltages as -50V, only the bottom part of the sensor carries spectral information. This is an effect of the low hole mobility and the longer range the electrons have to travel in a low field.
  • References (13)
    13 references, page 1 of 2

    [1] L.-A Hamel et al., Charge transport and signal generation in CdTe pixel detectors , Nucl. Instrum. Meth. A 380 (1996) P238.

    [2] J. Tanguay et al., The role of x-ray Swank factor in energy-resolving photon-counting imaging , Med. Phys. 37 (2010) 6205.

    [3] C. Fro¨jdh, H. Graafsma, B. Norlin, H.E. Nilsson and C. Ponchut, Erratum to: “Characterization of a pixellated CdTe detector with single-photon processing readout”: [Nucl. Instr. and Meth. A 563 (2006) 128-132], Nucl. Instrum. Meth. A 574 (2007) P205.

    [4] M. Maiorino et al., Charge-sharing observations with a CdTe pixel detector irradiated with a 57Co source, Nucl. Instrum. Meth. A 563 (2006) P177.

    [5] X. Llopart et al., Timepix, a 65k programmable pixel readout chip for arrival time, energy and/or photon counting measurements,, Nucl. Instrum. Meth. A 581 (2007) P485.

    [6] V. Kraus et al., FITPix - fast interface for Timepix pixel detectors, 2011 JINST 6 C01079.

    [7] D. Turecek et al., Pixelman: a multiplatform data acquisition and processing software for Medipix2, Timepix and Medipix3 detectors, 2001 JINST 6 C01046.

    [8] J. Jakubek, Energy-sensitive X-ray radiography and charge sharing effect in pixelated detector Nucl. Instrum. Meth. 607 (2009) P192.

    [9] J. Jakubek et al., Pixel detectors for imaging with heavy charged particles, Nucl. Instrum. Meth. 591 (2007) P155.

    [10] J. Jakubek et al., Spectrometric properties of TimePix pixel detector for X-ray color and phase sensitive radiography, IEEE Nucl. Sci. Simp. Conf. Rec. (2007).