Verification of the indoor GPS system, by comparison with calibrated coordinates and by angular reference

Article English OPEN
Muelaner, J.E ; Wang, Zheng ; Martin, O. ; Jamshidi, J. ; Maropoulos, Paul G (2012)

This paper details work carried out to verify the dimensional measurement performance of the Indoor GPS (iGPS) system; a network of Rotary-Laser Automatic Theodolites (R-LATs). Initially tests were carried out to determine the angular uncertainties on an individual R-LAT transmitter-receiver pair. A method is presented of determining the uncertainty of dimensional measurement for a three dimensional coordinate measurement machine. An experimental procedure was developed to compare three dimensional coordinate measurements with calibrated reference points. The reference standard used to calibrate these reference points was a fringe counting interferometer with the multilateration technique employed to establish three dimensional coordinates. This is an extension of the established technique of comparing measured lengths with calibrated lengths. The method was found to be practical and able to establish that the expanded uncertainty of the basic iGPS system was approximately 1 mm at a 95% confidence level. Further tests carried out on a highly optimized version of the iGPS system have shown that the coordinate uncertainty can be reduced to 0.25 mm at a 95% confidence level.
  • References (22)
    22 references, page 1 of 3

    Anchini, R., G. Di Leo, C. Liguori, A. Paolillo, A. Pietrosanto and G. Strazzullo (2007). Metrological verification of 3D scanners: A preliminary approach, San Jose, CA, United States, SPIE -International Society for Optical Engineering, Bellingham WA, WA 98227-0010, United States.

    ASME (2006). Performance Evaluation of Laser-Based Spherical Coordinate Measurement Systems. B89.4.19.

    BSI - British Standards Institution (2002). Geometrical Product Specifications (GPS) ­ Acceptance and reverification tests for coordinate measuring machines (CMM) ­ Part 2: CMMs used for measuring size. BS EN ISO 10360-2:2002.

    BSI (1995). General Metrology - Part 3: Guide to the expression of uncertainty in measurement (GUM). PD 6461-3.

    Calkins, J. M. (2002). Quantifying Coordinate Uncertainty Fields in Coupled Spatial Measurement Systems Mechanical Engineering. Blacksburg, Virginia Polytechnic Institute and State University. PhD: 226.

    Estler, W. T., K. L. Edmundson, G. N. Peggs and D. H. Parker (2002). "Large-scale metrology - An update." CIRP Annals - Manufacturing Technology 51(2): 587-609.

    Faro (2007). Faro Laser Tracker Xi. 2008.

    Flack, D. (2001). Measurement Good Practice Guide No. 42: CMM Verification, National Physical Laboratory.

    Hedges, T. M., H. Takagi, T. Pratt and M. J. Sobel (2003). Position Measurement System and Method Using Cone Math Calibration. U. S. Patent, Arc Second.

    Hughes, B., A. Forbes, W. Sun, P. G. Maropoulos, J. E. Muelaner, J. Jamshidi and Z. Wang (2010). iGPS Capability Study. NPL Report. Teddington, NPL: 35.