Transverse rotation and longitudinal translation during prosthetic gait - a literature review

Article English OPEN
Twiste, M ; Rithalia, S
  • Publisher: Rehabilitation Research and Development Service, Department of Veterans Affairs
  • Subject: R | health_and_wellbeing

Improved technology allows for more accurate gait\ud analysis to increase awareness of nonoptimized prosthetic gait\ud patterns and for the manufacture of sophisticated prosthetic\ud components to improve nonoptimized gait patterns. However,\ud prescriptions are often based on intuition rather than rigorous\ud research findings for evidence-based practice. The number of\ud studies found in the literature that are based on prosthetic\ud research regarding transverse rotation and longitudinal translation\ud is small when compared to topics regarding other types of\ud movements. Some design criteria for prosthetic components\ud described in those studies that permit transverse rotation and\ud longitudinal translation can be found in current designs. However,\ud little research has been conducted to establish their effectiveness\ud on the gait parameters and residual limb. This\ud literature review is an investigation into these motions between\ud the socket and the prosthetic foot, with particular reference to\ud gait characteristics and prosthetic design criteria.
  • References (54)
    54 references, page 1 of 6

    1. Vitali M, Robinson KP, Andrews BG, Harris EE, Redhead RG. Amputations and prostheses. 2nd ed. London: Bailière Tindall; 1986. p. 4.

    2. DiAngelo DJ, Winter DA, Ghista DN, Newcombe WR. Performance assessment of the Terry Fox jogging prosthesis for above-knee amputees. J Biomech 1989;22(6,7): 543-58.

    3. Buckley JG, Jones FJ, Birch KM. Oxygen consumption during ambulation: comparison of using a prosthesis with and without a teletorsion pylon. Arch Phys Med Rehabil 2002;83:576-81.

    4. Gailey RS, Lawrence D, Burditt C, Spyropoulos C, Newell C, Nash MS. The CAT-CAM socket and quadrilateral socket: a comparison of energy cost during ambulation. Prosthet Orthot Int 1993;17:95-100.

    5. Levens AS, Inman VT, Blosser JA. Transverse rotation of the segments of the lower extremity in locomotion. J Bone Joint Surg Am 1948;30-A(4):859-72.

    6. Lafortune MA, Cavanagh PR, Sommer HJ, Kalenak A. Foot inversion-eversion and knee kinematics during walking. J Orthop Res 1994;12:412-20.

    7. Nester CJ, Linden van der ML, Bowker P. Some effects of foot orthoses on joint motion and moments, and ground reaction forces. In: Kenney L, Mickelborough J, Nester C, Rithalia S, editors. Proceedings of the Conference of Biomechanics of the Lower Limb in Health, Disease and Rehabilitation; 2001 Sep 10-12; Salford, UK. p. 134-35.

    8. Cappozzo A, Catani F, Leardini A, Benedetti MG, Della Croce U. Position and orientation in space of bones during movement: experimental artefacts. Clin Biomech 1996; 11:90-100.

    9. Lamoureux LW, Radcliffe CW. Functional analysis of the UC-BL shank axial rotation device. Prosthet Orthot Int 1977;1:114-18.

    10. Manter JT. Movements of the subtalar and transverse tarsal joints. Anat Rec 1941;80(4):397-410.

  • Metrics
    0
    views in OpenAIRE
    0
    views in local repository
    235
    downloads in local repository

    The information is available from the following content providers:

    From Number Of Views Number Of Downloads
    University of Salford Institutional Repository - IRUS-UK 0 235
Share - Bookmark