Ultimate axial load capacity of v-band clamp joints.

Part of book or chapter of book English OPEN
Muller, M ; Barrans, Simon (2009)
  • Publisher: University of Huddersfield
  • Subject: TL | T1

Band clamps with a flat bottomed V-section are used to connect a pair of circular flanges to provide a joint with significant axial strength. Despite the wide application of V-band clamps, their behaviour is not fully understood and the ultimate axial strength is currently only available from physical testing. This physical testing has indicated that the ultimate strength is determined by two different types of structural deformation, an elastic deformation mode and a plastic deformation mode. Initial finite element analysis work has demonstrated that analysis of this class of problem is not straightforward. This paper discusses the difficulties encountered when simulating this type of component interaction where contact is highly localised and contact pressures are high and therefore presents a finite element model to predict the ultimate axial load capacity of V-band clamps.
  • References (10)

    Shoghi K (2003) Stress and Strain Analysis of flat and V-section band clamps PhD Thesis Huddersfield

    NASA (2000) Marman clamp system design guidelines. Guideline GD-ED-2214, Goddard Space Flight Centre

    Shoghi K, Barrans S M, Rao H V (2004) Stress in V-section band clamps Proceedings of the Institution of Mechanical Engineers 218 251-261

    Shoghi K, Barrans S M, Rao, H. V. (2003) Classical and finite element analysis of V-band retainers NAFEMS World Congress (Orlando Florida)

    Shoghi K, Barrans S M, Ramasamy P (2006) Axial load capacity of V-section band clamp joints 8th International Conference on Turbochargers and Turbocharging (London) pp273-285

    Dixit, P.M. and U.S. Dixit, Modeling of Metal Forming and Machining Processes by Finite Element and Soft Computing Methods. 2008, London: Springer. p 101.

    Meyers, M.A. and K.K. Chawla, Mechanical Behavior of Materials. 1999, London: Prentice-Hall International (UK) Ltd.

    Tehrani, M.S., et al., Localised edge buckling in cold roll-forming of symmetric channel section. Thin-walled structures, 2006. 44: p. 184-196.

    Barrans, S.M. and M. Muller, Finite element prediction of the ultimate axial load capacity of V-section band clamps, in 7th International Conference on Modern Practice in Stress and Vibration Analysis. 2009: Cambridge.

    Brown, I. 11-05-2009, Teconnex Ltd.: Keighley.

  • Metrics
    0
    views in OpenAIRE
    0
    views in local repository
    239
    downloads in local repository

    The information is available from the following content providers:

    From Number Of Views Number Of Downloads
    University of Huddersfield Repository - IRUS-UK 0 239
Share - Bookmark