Loading
- 1
- 2
- publication . Article . Other literature type . Preprint . 2013Open Access EnglishAuthors:CALICE Collaboration; Adloff, C.; Blaising, J. -J.; Chefdeville, M.; Drancourt, C.; Gaglione, R.; Geffroy, N.; Karyotakis, Y.; Koletsou, I.; Prast, J.; ...handle: 1854/LU-5334038 ,Publisher: Inst. of PhysicsProject: NSERC , EC | AIDA (262025)
Comment: 27 pages, 17 figures, accepted for publication in JINST
- publication . Article . Preprint . 2015Open Access EnglishAuthors:Bilki, B.; Repond, J.; Khan, A.; Verdugo, A.; Corriveau, F.; Bobchenko, B.; Chistov, R.; Chadeeva, M.; Danilov, M.; Drutskoy, A.; ...Publisher: HAL CCSDProject: EC | AIDA (262025)
Comment: 26 pages, 16 figures, JINST style, changes in the author list, typos corrected, new section added, figures regrouped. Accepted for publication in JINST
- publication . Article . Preprint . 2015Open AccessAuthors:The CALICE Collaboration; Bilki, B.; Repond, J.; Schlereth, J.; Xia, L.; Deng, Z.; Li, Y.; Wang, Y.; Yue, Q.; Yang, Z.; ...handle: 1854/LU-7283342Publisher: Elsevier BVProject: EC | AIDA (262025), ANR | P2IO (10-LABX-0038)
A detailed study of hadronic interactions is presented using data recorded with the highly granular CALICE silicon-tungsten electromagnetic calorimeter. Approximately 350,000 selected negatively charged pion events at energies between 2 and 10 GeV have been studied. The...
- publication . Article . Other literature type . 2018Open Access EnglishAuthors:D.H. Kim; Taikan Suehara; M. Nishiyama; M. Matysek; T. Sakuma; P. Göttlicher; V. Rusinov; S. Lu; M. Frotin; H.L. Tran; ...Publisher: HAL CCSDProject: EC | AIDA (262025), NSERC , EC | AIDA-2020 (654168)
This paper presents results obtained with the combined CALICE Scintillator Electromagnetic Calorimeter, Analogue Hadronic Calorimeter and Tail Catcher & Muon Tracker, three high granularity scintillator-SiPM calorimeter prototypes. The response of the system to pion...
- publication . Article . Preprint . 2015Open Access EnglishAuthors:Abramowicz, H.; Abusleme, A.; Bozovic-Jelisavcic, I.; Castro, E.; Chelkov, G.; Coca, C.; Daniluk, W.; Dumitru, L.; Elsener, K.; Fadeyev, V.; ...Publisher: Inst. of PhysicsProject: EC | MC-PAD (214560), MESTD | Physics and Detector R&am... (171012), EC | AIDA (262025)
Detector-plane prototypes of the very forward calorimetry of a future detector at an e+e- collider have been built and their performance was measured in an electron beam. The detector plane comprises silicon or GaAs pad sensors, dedicated front-end and ADC ASICs, and an...
- publication . Preprint . Other literature type . Article . 2019Open Access EnglishAuthors:Norbert Meyners; Ingrid-Maria Gregor; Ulrich Kötz; Marcel Stanitzki; Jan Dreyling-Eschweiler; Natalia Potylitsina-Kube; Anne Schütz; Ralf Diener; Uwe Krämer; Heiko Ehrlichmann; ...Project: EC | AIDA (262025), EC | AIDA-2020 (654168)
DESY Hamburg operates a test beam facility with three independent beam lines at the DESY II synchrotron. It is world-wide one of very few facilities providing test beams in the GeV range. To this end, it offers electron/positron beams with user-selectable momenta from 1...
- publication . Article . Preprint . 2013Validation of GEANT4 Monte Carlo Models with a Highly Granular Scintillator-Steel Hadron CalorimeterOpen Access EnglishAuthors:Adloff, C.; Blaha, J.; Francis, K.; Tarkovsky, E.; Kirikova, N.; Kozlov, V.; Smirnov, P.; Soloviev, Y.; Buzhan, P.; Ilyin, A.; ...Publisher: JINSTProject: NSERC , EC | AIDA (262025)
Calorimeters with a high granularity are a fundamental requirement of the Particle Flow paradigm. This paper focuses on the prototype of a hadron calorimeter with analog readout, consisting of thirty-eight scintillator layers alternating with steel absorber planes. The ...
- publication . Article . Preprint . 2019Open Access EnglishAuthors:M. Kiehn; M. Kiehn; Hyeon Jin Kim; D. Haas; D. Pitzl; L. Huth; M. Keil; P. Ahlburg; Joern Grosse-Knetter; J. Weingarten; ...handle: 11104/0312581Publisher: JINSTProject: EC | AIDA (262025), EC | AIDA-2020 (654168)
EUDAQ is a generic data acquisition software developed for use in conjunction with common beam telescopes at charged particle beam lines. Providing high-precision reference tracks for performance studies of new sensors, beam telescopes are essential for the research and...
- publication . Other literature type . Article . 2017Open Access EnglishAuthors:Tracker Group of the CMS Collaboration; Adam, W.; Steininger, H.; Bloch, D.; Bonnin, C.; Brom, J. M.; Chabert, E.; Chanon, N.; Charles, L.; Conte, E.; ...Publisher: KarlsruheProject: EC | AIDA (262025)
The high luminosity upgrade of the Large Hadron Collider, foreseen for 2026, necessitates the replacement of the CMS experiment’s silicon tracker. The innermost layer of the new pixel detector will be exposed to severe radiation, corresponding to a 1 MeV neutron equival...
- publication . Article . Preprint . 2014Open Access EnglishAuthors:Adloff, C.; Blaising, J -J; Repond, J.; Miyazaki, Y.; Sudo, Y.; Ueno, H.; Yoshioka, T.; Dauncey, P. D.; Gil, E Cortina; Mannai, S.; ...handle: 1854/LU-6832613Publisher: HAL CCSDProject: NSERC , EC | AIDA (262025)
Comment: 24 pages including author list, 9 figures, published in JINST